Operation
Parameter
4 - 14
4.5.3 Parameter
description
:
Number
Symbol
Initial value
Unit
Setting range
1
AMS
0000
Refer description
Amplifier setting
Used to select the absolute position detection.
2
REG
0000
Refer description
Regenerative brake resistor
CAUTION:
Wrong setting may cause the regenerative brake option to burn.
NOTE:
If the regenerative brake option selected is not for use with the servo amplifier, parameter error (37) occurs.
3
0080
Reserved
Do not change this parameter.
4
0000
Reserved
Do not change this parameter.
5
1
Reserved
Do not change this parameter.
Tab. 4-13:
Parameter list details (1)
0
0
0
Positioning
0: Standard (incremental)
1: Absolute position detection system
0
0
0
0
Regenerative selection brake option
00: No brake resistor
01: FR-RC, FR-BU
05: MR-RFH220-40
08: MR-RFH400-13
09: MR-RFH400-13
0B: MR-RFH400-6.7
0C: MR-RFH400-6.7
10: MR-RFH75-40
11: MR-RFH75-40
Servo amplifier 200V
Regenerative selection brake option
00: No brake resistor
01: FR-RC-H
, FR-BU-H
80: MR-RB3H-4
81: MR-RB5H-4/MR-PWR-T-600-80
82: MR-RB3G-4
83: MR-RB5G-4/MR-PWR-T-600-47
84: MR-RB34-4
85: MR-RB54-4/MR-PWR-T-600-26
86: MR-RB1L-4/MR-PWR-T-150-270
87: MR-RB3M-4/MR-PWR-T-400-120
Servo amplifier 400V
Содержание MELSERVO MRJ2S-B
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...VIII ...
Страница 18: ...Contents XII ...
Страница 48: ...Introduction System configuration 1 30 ...
Страница 58: ...Installation General environmental conditions 2 10 ...
Страница 86: ...Connection Station number setting 3 28 ...
Страница 122: ...Operation Gain 4 36 ...
Страница 134: ...Absolute position detection system General description 6 6 ...
Страница 146: ...Accessories Special accessories 7 12 ...
Страница 148: ...Maintenance and Inspection Life 8 2 ...
Страница 174: ...Specifications Standard specifications 10 16 ...
Страница 176: ...EMC Directives Requirements 11 2 ...
Страница 198: ...Index iv ...
Страница 199: ......