![Mitsubishi Electric MELSERVO MR-JET-G Series Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-jet-g-series/melservo-mr-jet-g-series_user-manual_239180047.webp)
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
45
1
[Pr. PB45.2_Notch depth selection]
Refer to the following table for details.
[Pr. PB46_Machine resonance suppression filter 3 (NH3)]
Set the notch frequency of the machine resonance suppression filter 3.
When [Pr. PB47.0 Machine resonance suppression filter 3 selection] is set to "1" (enabled), set the notch frequency with this
servo parameter.
[Pr. PB47_Notch shape selection 3 (NHQ3)]
Set forms of the machine resonance suppression filter 3.
[Pr. PB47.0_Machine resonance suppression filter 3 selection]
0: Disabled
1: Enabled
[Pr. PB47.1_Notch depth selection]
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Setting value
Depth [dB]
0
-40.0
1
-24.1
2
-18.1
3
-14.5
4
-12.0
5
-10.1
6
-8.5
7
-7.2
8
-6.0
9
-5.0
A
-4.1
B
-3.3
C
-2.5
D
-1.8
E
-1.2
F
-0.6
Initial value
Setting range
Ver.
4500 [Hz]
10 to 9000
A4
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Содержание MELSERVO MR-JET-G Series
Страница 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Страница 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Страница 163: ......