![Mitsubishi Electric MELSERVO MR-JET-G Series Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/mitsubishi-electric/melservo-mr-jet-g-series/melservo-mr-jet-g-series_user-manual_239180038.webp)
36
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
[Pr. PB19_Vibration suppression control 1 - Vibration frequency
(VRF11)]
Set the vibration frequency of vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (manual setting) is selected, set the vibration frequency with this servo
parameter.
If [Pr. PB25.0 Model adaptive control selection] is set to "2" (disabled), the vibration suppression control cannot be used.
The available range of [Pr. PB19 Vibration suppression control 1 - Vibration frequency] depends on the value in [Pr. PB07
Model control gain]. If the setting value of [Pr. PB19] exceeds the available range, the vibration suppression control is
disabled.
[Pr. PB20_Vibration suppression control 1 - Resonance
frequency (VRF12)]
Set the resonance frequency of vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (manual setting) is selected, set the resonance frequency with this servo
parameter.
If [Pr. PB25.0 Model adaptive control selection] is set to "2" (disabled), the vibration suppression control cannot be used.
The available range of [Pr. PB20 Vibration suppression control 1 - Resonance frequency] changes depending on the value in
[Pr. PB07 Model control gain]. If the setting value of [Pr. PB20] exceeds the available range, the vibration suppression control
is disabled.
[Pr. PB21_Vibration suppression control 1 - Vibration frequency
damping (VRF13)]
Set the damping of the vibration frequency for vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (manual setting) is selected, set the damping of the vibration frequency with this
servo parameter.
[Pr. PB22_Vibration suppression control 1 - Resonance
frequency damping (VRF14)]
Set the damping of the resonance frequency for vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (manual setting) is selected, set the damping of the resonance frequency with
this servo parameter.
Initial value
Setting range
Ver.
100.0 [Hz]
0.1 to 300.0
A4
Initial value
Setting range
Ver.
100.0 [Hz]
0.1 to 300.0
A4
Initial value
Setting range
Ver.
0.00
0.00 to 0.30
A4
Initial value
Setting range
Ver.
0.00
0.00 to 0.30
A4
Содержание MELSERVO MR-JET-G Series
Страница 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Страница 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Страница 163: ......