6 FUNCTIONAL SAFETY
6.2 Signal
337
6
Output device
The status monitor (SM) of the safety sub-functions is output as the output signal of the CN8-6/CN8-7 pin. The output device
can be assigned to the output signal of the CN8-6/CN8-7 pin with [Pr. PSD08 Output device selection DO1]. Refer to the
following for details.
For safety sub-function control by network, output via a network is possible. In that case, the output signal of the CN8-6/CN8-
7 pin can be used at the same time.
Device
Symbol
Connector pin No.
Function
Status of output pin
during operation
SSM output
SSMS
CN8A-6
CN8B-7
Indicates that the servo motor speed is equal to or less
than the SSM speed while speed monitoring by the SSM
function is in operation.
Closed
SBC output
SBCS
Outputs a control signal of the electromagnetic brake.
Open
STO output
STOS
This is a monitor output signal indicating that the STO
function is activated.
Open
SOS output
SOSS
This is a monitor output signal indicating that the servo
motor in the stop state is being monitored with the SS2/
SOS functions.
Open
SS1 output
SS1S
This is a monitor output signal indicating that the SS1
function is activated.
Open
SS2 output
SS2S
This is a monitor output signal indicating that the SS2/
SOS function is activated.
Open
SLS1 output
SLS1S
This is a monitor output signal indicating that the SLS
function 1 is activated.
Open
SLS2 output
SLS2S
This is a monitor output signal indicating that the SLS
function 2 is activated.
Open
SLS3 output
SLS3S
This is a monitor output signal indicating that the SLS
function 3 is activated.
Open
SLS4 output
SLS4S
This is a monitor output signal indicating that the SLS
function 4 is activated.
Open
SDIP output
SDIPS
This is a monitor output signal indicating that the SDI
function is activated.
Open
SDIN output
SDINS
This is a monitor output signal indicating that the SDI
function is activated.
Open
SLI output
SLIS
This is a monitor output signal indicating that the SLI
function is activated.
Open
SLT1 output
SLT1S
This is a monitor output signal indicating that the SLT
function 1 is activated.
Open
SLT2 output
SLT2S
This is a monitor output signal indicating that the SLT
function 2 is activated.
Open
SLT3 output
SLT3S
This is a monitor output signal indicating that the SLT
function 3 is activated.
Open
SLT4 output
SLT4S
This is a monitor output signal indicating that the SLT
function 4 is activated.
Open