336
6 FUNCTIONAL SAFETY
6.2 Signal
6.2
Signal
Explanation of signals
Input device
Assign a device to the input signal of the CN8-4/CN8-5 pin with [Pr. PSD02 Input device selection DI1]. Refer to the following
for details.
For safety sub-function control by network, input via a network is possible. Refer to the following for details.
Page 350 Safety sub-function control by network
Device
Symbol
Connector pin No.
Function
State of the input pin
in which the function
is enabled
STO command
STOC
CN8A-4
CN8B-5
The STO function is activated by the STO command.
Open
SS1 command
SS1C
The SS1 function is activated by the SS1 command.
Open
SS2 command
SS2C
The SS2/SOS function is activated by the SS2
command.
Open
SLS1 command
SLS1C
The SLS function 1 is activated by the SLS1 command.
[Pr. PSA07 SLS deceleration monitor time 1] and [Pr.
PSA11 SLS speed 1] are used as parameters.
Open
SDIP command
SDIPC
The SDI function is activated in the address increasing
direction by the SDIP command.
Open
SDIN command
SDINC
The SDI function is activated in the address decreasing
direction by the SDIN command.
Open
SLI command
SLIC
The SLI function is activated by the SLI command.
Open
SLT1 command
SLT1C
The SLT function 1 is activated by the SLT1 command.
[Pr. PSB10 SLT torque upper limit value 1] and [Pr.
PSB14 SLT torque lower limit value 1] are used as
parameters.