246
4 APPLICABLE FUNCTIONS
4.6 Drive recorder
Servo parameter/object dictionary
This section shows the servo parameters and object dictionary related to the drive recorder.
If [Pr. PF80.0 Drive recorder - Operation mode selection] = "0" (automatic setting mode) (initial value), the setting values of
[Pr. PF81 Drive recorder - Sampling operation selection] to [Pr. PF94 Drive recorder - Digital channel setting 4] are disabled.
The drive recorder operates automatically with the alarm trigger.
Servo parameter [G] [WG]
Servo
parameter
Symbol
Name
Outline
PF80.0
DRMC
Drive recorder - Operation mode
selection
Select the operation mode of drive recorder.
0: Automatic setting mode (initial value)
1: Manual setting mode
PF80.2-3
DRMC
Drive recorder - Sampling cycle
selection
Set the sampling cycle.
00: Automatic (250
μ
s) (initial value)
05: 250
μ
s
06: 500
μ
s
07: 1 ms
08: 2 ms
09: 4 ms
0A: 8 ms
0B: 16 ms
0C: 32 ms
0D: 64 ms
0E: 128 ms
0F: 256 ms
10: 512 ms
11: 1.024 s
PF81.0
DRMS
Drive recorder - Sampling start
selection
Select to start sampling in manual setting mode.
0: Stop sampling (initial value)
1: Start a single sampling
2: Start a consecutive sampling
PF82.0
DRTM
Drive recorder - Trigger mode
selection
Select the trigger mode.
0: Alarm trigger (initial value)
1: Analog trigger/digital trigger
PF82.1
DRTM
Drive recorder - Trigger binding
condition selection
Select the binding condition of the trigger.
0: Disabled (initial value)
1: Logical AND of trigger signals
2: Logical OR of trigger signals
PF82.2
DRTM
Drive recorder - Trigger operation
selection 1
Select whether sampling starts when the channel set in [Pr. PF84.0-1 Drive recorder
- Trigger channel selection 1] exceeds the set trigger level (rising) or starts when it
falls below the set trigger level (falling).
0: Rising (initial value)
1: Falling
PF82.3
DRTM
Drive recorder - Trigger operation
selection 2
Select whether sampling starts when the channel set in [Pr. PF84.2-3 Drive recorder
- Trigger channel selection 2] exceeds the set trigger level (rising) or starts when it
falls below the set trigger level (falling).
0: Rising (initial value)
1: Falling
PF83.0
**DRTAX
Drive recorder - Trigger axis
common selection
For a multi-axis servo amplifier, select whether to store only the data of the axis in
which the conditions are met or to store the data of all axes when using the manual
setting mode and the trigger conditions are met on an analog trigger or digital trigger.
0: Disabled (initial value)
1: Enabled
PF84.0-1
DRTC
Drive recorder - Trigger channel
selection 1
Set trigger channel No. 1.
Initial value: 01h (Analog channel 1)
PF84.2-3
DRTC
Drive recorder - Trigger channel
selection 2
Set trigger channel No. 2.
Initial value: 81h (Digital channel 1)
PF84.4-5
DRTC
Drive recorder - Trigger position
setting
For the total sampling time, set the trigger position in hexadecimal from 0 to 100 %.
Initial value: 5Ah (90 [%])
PF85
DRTL1
Drive recorder - Trigger level
setting 1
Set the trigger level of [Pr. PF84.0-1 Drive recorder - Trigger channel selection 1] in
decimal.
Initial value: 0