150
3 BASIC FUNCTION
3.19 Quick stop [G] [WG]
Timing chart
When [Quick stop option code (Obj. 605Ah)] is set to "2"
The servo motor decelerates to a stop with [Quick stop deceleration (Obj. 6085h)], and the state shifts to "Switch On
Disabled".
MBR
ON
OFF
ON
OFF
0 r/min
[Quick stop deceleration
(Obj. 6085h)]
ON
OFF
Switch On Disabled
Quick Stop Active
Operation Enabled
Quick stop command
(Enabled)
Rated speed
Servo motor speed
Command
Zero speed ([Pr. PC17])
Deceleration time
Base circuit
(Energy supply to
the servo motor)
(Electromagnetic
brake interlock)
(Enabled)