38
3 STRUCTURE
3.2 Switch setting and display of the servo amplifier
Functions at alarm occurrence
• The current alarm is displayed in any mode.
• Even during alarm occurrence, the other screen can be viewed by pressing the button in the operation area. At this time,
the decimal point in the fifth digit remains blinking.
• Remove the cause of the alarm and clear the cause of the alarm in any of the following methods.
Cycle the power.
Press "SET" on the current alarm display.
Turn on RES (Reset).
• Clear the alarm history with [Pr. PC18].
• Press "UP" or "DOWN" to move to the next history.
Parameter mode
Parameter mode transition
After selecting the corresponding servo parameter mode with "MODE" button, pressing "UP" or "DOWN" button changes the
display as follows.
[Pr. PA01]
[Pr. PA02]
[Pr. PB01]
[Pr. PB02]
[Pr. PC01]
[Pr. PC02]
[Pr. PD01]
[Pr. PD02]
[Pr. PE01]
[Pr. PE02]
[Pr. PF01]
[Pr. PF02]
[Pr. Po01]
[Pr. Po02]
[Pr. PS01]
[Pr. PS02]
[Pr. PL01]
[Pr. PL02]
[Pr. PT01]
[Pr. PT02]
[Pr. PN01]
[Pr. PN02]
[Pr. PU01]
[Pr. PU02]
From alarm
mode
Basic setting
servo parameters
Gain/filter
servo parameters
Extension setting
servo parameters
I/O setting
servo parameters
Extension setting 2
servo parameters
Extension setting 3
servo parameters
End
End
End
End
End
End
Top
Top
Top
Top
Top
Top
For manufacturer
setting
For manufacturer
setting
Motor extension
setting servo
parameters
End
End
End
Top
Top
Top
For manufacturer
setting
To state
transition
mode
For manufacturer
setting
For manufacturer
setting
End
End
End
Top
Top
Top