116
4 APPLICABLE FUNCTIONS
4.3 Drive recorder
4.3
Drive recorder
This function continuously monitors the servo amplifier status and records the state transition before and after an alarm for a
fixed period of time.
By using MR Configurator2 via a network or USB connection, the data recorded inside the servo amplifier can be read in order
to analyze alarms.
An engineering tool (such as GX LogViewer and MR Configurator2) can be used to display monitor and waveform data, and
reference to servo parameter data and output files in the drive recorder.
• When using MR Configurator2
• When using GX LogViewer
• The drive recorder does not operate in the following cases.
When using the graph function with an engineering tool.
When using the machine analyzer function.
When [Pr. PF21 Drive recorder switching time setting] is set to "-1" (Drive recorder function disabled).
• To read recorded data from the drive recorder by using the FTP server function, use a network supporting
the function.
• When the drive recorder data (JSON) files on the server are listed by using the FTP server function, the file
size will appear as 0 bytes.
MR Configurator2
Ethernet
USB
GX LogViewer
Reading data recorded
by the drive recorder
Data analysis
Alarm occurrence data is automatically recorded.
Monitor data
Alarm occurrence
Servo amplifier
Waveform data
Engineering tool
Ethernet port
Servo parameter data
USB port
File output
Log file
Reading output files
GX LogViewer
FTP
Reading data recorded
by the drive recorder
Data analysis
Alarm occurrence data is automatically recorded.
Alarm occurrence
Servo amplifier
Waveform data
Engineering tool
Ethernet port
Log file