52
8 Manufacturer Specific Control Object
8.5 [Dynamic relay ON/OFF number (Obj. 2C1Ah)]
8.5
[Dynamic relay ON/OFF number (Obj. 2C1Ah)]
[Dynamic relay ON/OFF number (Obj. 2C1Ah: 00h)]
Description
The number of times that the dynamic brake of the servo amplifier has been used is returned.
8.6
[Machine diagnostic status (Obj. 2C20h)]
[Machine diagnostic status (Obj. 2C20h: 00h)]
Description
The machine diagnostic status is returned.
[Bit 0 to 3: Friction estimation status at forward rotation]
0: Estimation in progress. (normal)
1: Estimation has finished. (normal)
2: The motor may have rotated/traveled more frequently in one direction than the other. (warning)
3: The servo motor speed may be too slow for friction estimation. (warning)
4: The change in the servo motor speed may be too small for friction estimation. (warning)
5: The acceleration/deceleration time constants may be too short for friction estimation. (warning)
6: The elapsed operation time may be insufficient. (warning)
When warning conditions for 2 to 6 are met at the same time, the lower number takes priority.
Even if a warning occurs during estimation, upon completion the status will change to "Estimation has finished".
[Bit 4 to 7: Friction estimation status at reverse rotation]
0: Estimation in progress. (normal)
1: Estimation has finished. (normal)
2: The motor may have rotated/traveled more frequently in one direction than the other. (warning)
3: The servo motor speed may be too slow for friction estimation. (warning)
4: The change in the servo motor speed may be too small for friction estimation. (warning)
5: The acceleration/deceleration time constants may be too short for friction estimation. (warning)
6: The elapsed operation time may be insufficient. (warning)
When warning conditions for 2 to 6 are met at the same time, the lower number takes priority.
Even if a warning occurs during estimation, upon completion the status will change to "Estimation has finished".
[Bit 8 to 11: Vibration estimation status]
0: Estimation in progress.
1: Estimation has finished.
[Bit 12 to 15: reserved]
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RO
Impossible
00000000h to
FFFFFFFFh
number of times
Impossible
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U16
RO
Impossible
0000h to FFFFh
Impossible
Содержание MELSERVO J5 Series
Страница 2: ......
Страница 18: ...16 1 SUMMARY OF OBJECT DICTIONARY 1 1 Structure MEMO ...
Страница 121: ...18 Cyclic Synchronous Position Mode Objects 18 3 Torque offset Obj 60B2h 119 18 MEMO ...
Страница 125: ......