2 General Objects
2.1 [Device Type (Obj. 1000h)]
17
2
2
General Objects
2.1
[Device Type (Obj. 1000h)]
[Device Type (Obj. 1000h: 00h)]
Description
Indicates supported profile information. The value "00020192h" which indicates a servo drive defined with the CiA 402 profile
is returned.
2.2
[Error Register (Obj. 1001h)]
[Error Register (Obj. 1001h: 00h)]
Description
Whether an alarm has occurred is returned. When a multi-axis servo amplifier is used, the alarm occurrence in each axis is
indicated.
2.3
[Manufacturer Device Name (Obj. 1008h)]
[Manufacturer Device Name (Obj. 1008h: 00h)]
Description
The model name of the servo amplifier is returned.
Ex.
If MR-J5-10G is used, the model name is returned as shown below.
"MR-J5-10G " (Empty spaces after the model name are filled with blank spaces to make the name 32 characters long.)
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U32
RO
Impossible
00020192h
00020192h
(fixed)
Impossible
Bit
Symbol
Description
0 to 7
0192h (CiA 402)
8 to 15
0002h (Servo drive)
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
U8
RO
Impossible
00h to 01h
Impossible
Bit
Symbol
Description
0
Always on while an alarm is occurring.
1 to 7
Data Type
Access
Mapping
Default
Range
Units
Save
Parameter
VISIBLE
STRING
RO
Impossible
Impossible