338
9 USING FUNCTIONAL SAFETY [G] [WG]
9.6 Connecting I/O interfaces
9.6
Connecting I/O interfaces
Refer to this section before connecting I/O interfaces to external devices.
Source input
This is an input circuit in which the anode of the photocoupler is the input terminal. Transmit signals from a source (open-
collector) type transistor output, relay switch, etc.
Sink input
This is an input circuit in which the photocoupler cathode side is the input terminal. Transmit signals from a sink (open-
collector) type transistor output, relay switch, etc.
SDICOM
SDIA
SDIB
24 V IN
0 V IN
Approx. 4.4 k
Ω
Approx. 4.4 k
Ω
24 V DC
Control
output 1
Control
output 2
External device
24 V DC, 5 mA
24 V DC, 5 mA
SDICOM
SDIA
SDIB
24 V IN
0 V IN
Approx. 4.4 k
Ω
Approx. 4.4 k
Ω
24 V DC
Control
output 1
Control
output 2
External device
24 V DC, 5 mA
24 V DC, 5 mA
Содержание MELSERVO-J5 MR-J5-G Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 473: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 471 12 MEMO ...
Страница 477: ......