Appendix 12 List of registration objects
629
A
Servo transient transmission function
The servo transient transmission function is used to monitor data in the servo amplifier with the servo system controller. In the
servo transient transmission function, the following data can be monitored by setting Index, Sub Index, and Data Type for
each command.
For details of usage, the unit of data types, and others, refer to RD77GF Simple Motion Module User's Manual.
Index
Sub Index Data Type Access
Data type
Description
608Fh
1
U32
ro
Position encoder resolution
The encoder resolution is displayed.
When the linear servo motor is connected, the virtual resolution
per revolution is returned. When the fully closed loop system is
used, the number of load-side pulses per servo motor-side
revolution is returned.
2D38h
0
U32
ro
Scale measurement encoder
resolution
For rotary type, for example, when an encoder of 4194304
pulse/rev is connected, the object value is 4194304.
The value is always 0 except for rotary type.
1008h
0
VISIBLE
STRING
ro
Manufacturer Device Name
The number of characters of the servo amplifier name (N) is
displayed.
1 to N
The servo amplifier name is displayed.
100Ah
0
VISIBLE
STRING
ro
Manufacturer Software Version
The number of characters of the servo amplifier software
version (N) is displayed.
1 to N
The software version of the servo amplifier is displayed.
2C18h
0
U32
ro
Power ON cumulative time
The cumulative time after power on of the servo amplifier is
displayed.
2C19h
0
U32
ro
Number of inrush relay ON/OFF times The number of on and off for inrush relay of the servo amplifier
is displayed.
2A00h to
2A0F
1
U32
ro
Alarm No.
The alarm history/detail #1 to #16 are displayed. (Hexadecimal)
2A00h to
2A0F
2
U32
ro
Alarm time (Hour)
The alarm occurrence time #1 to #16 are displayed.
(Hexadecimal)
2B0Fh
0
U16
ro
Bus voltage
The voltage of main circuit converter (between P+ and N-) is
displayed.
2B08h
0
U16
ro
Regenerative load ratio
The ratio of regenerative power to permissible regenerative
power is displayed in %.
2B09h
0
U16
ro
Effective load ratio
The continuous effective load current is displayed.
The effective value is displayed considering a rated current as
100%.
2B0Ah
0
U16
ro
Peak load ratio
The maximum torque generated is displayed.
The highest value in the past 15 s is displayed, with the rated
torque being 100%.
2B0Eh
0
U16
ro
Load to motor inertia ratio
The set ratio of the load inertia moment to the servo motor shaft
inertia moment is displayed.
2B12h
0
I32
ro
Load-side encoder information 1
When an incremental type linear encoder is used for the load-
side encoder, the Z-phase counter of the load-side encoder is
displayed by encoder pulses.
When an absolute position type linear encoder is used for the
load-side encoder, the encoder absolute position is displayed.
2B13h
0
I32
ro
Load-side encoder information 2
When an incremental type linear encoder is used for the load-
side encoder, the display shows 0.
When an absolute position type linear encoder is used for the
load-side encoder, the display shows 0.
When a rotary encoder is used for the load-side encoder, the
display shows the multi-revolution counter value of the encoder.
2B17h
0
I16
ro
Temperature of motor thermistor
The thermistor temperature is displayed for the servo motor with
a thermistor.
For the servo motor without thermistor, "9999" is displayed.
For the servo motor with a thermistor, refer to each servo motor
instruction manual.
2B2Dh
0
I16
ro
Unit power consumption
The module power consumption is displayed. (16 bit version)
The positive value is displayed in power running. The negative
value is displayed in regeneration.
2B2Eh
0
I32
ro
Unit total power consumption
The module integral power consumption is displayed.