1 FUNCTIONS AND CONFIGURATION
1.8 Configuration including peripheral equipment
59
1
1.8
Configuration including peripheral equipment
• Equipment other than the servo amplifier and servo motor are optional or recommended products.
• When using the MR-J4-_GF-RJ servo amplifier with the DC power supply input, refer to the following.
Page 563 When using the servo amplifier with the DC power supply input
200 V class
■
MR-J4-200GF(-RJ) or less
The diagram shows MR-J4-20GF-RJ.
CAUTION
• Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo amplifier may cause a malfunction.
• The CN1A and CN1B connectors are designed for CC-Link IE Field Network only. Do not connect these connectors to other than CC-Link IE Field Network.
Doing so may cause a malfunction.
CN4
Line noise
filter
(FR-BSF01)
CN5
Regenerative
option
P+
C
L11
L21
P3
P4
Servo motor
Personal
computer
MR Configurator2
CN3
CN8
CN2
CN2L
*4
W
V
U
Magnetic
contactor
*3
L1
L2
L3
*1
(MC)
Power factor
improving DC
reactor
(FR-HEL)
Junction
terminal block
Safety relay or
MR-J3-D05
safety logic unit
Battery
Molded-case
circuit breaker
(MCCB)
R S T
Power supply
*2
D
*5
CN1A
CN1B
Servo system controller or
servo amplifier
Servo system controller or
servo amplifier