7 SPECIAL ADJUSTMENT FUNCTIONS
7.3 Tough drive function
267
7
7.3
Tough drive function
Set enable/disable of the tough drive function with [Pr. PA20 Tough drive setting].
Page 183 Basic setting parameters ([Pr. PA_ _ ])
This function makes the equipment continue operating even under the condition that an alarm occurs. The tough drive
functions are the vibration tough drive and the instantaneous power failure tough drive.
Vibration tough drive function
This function prevents vibration by resetting a filter instantaneously when machine resonance occurs due to varied vibration
frequency caused by machine aging.
To reset the machine resonance suppression filters with the function, [Pr. PB13 Machine resonance suppression filter 1] and
[Pr. PB15 Machine resonance suppression filter 2] should be set in advance.
Set [Pr. PB13] and [Pr. PB15] as follows.
• One-touch tuning execution
• Manual setting
Page 192 Gain/filter setting parameters ([Pr. PB_ _ ])
The vibration tough drive function operates when a detected machine resonance frequency is within
30% for a value set in
[Pr. PB13 Machine resonance suppression filter 1] or [Pr. PB15 Machine resonance suppression filter 2].
To set a detection level of the function, set sensitivity in [Pr. PF23 Vibration tough drive - Oscillation detection level].
• Resetting [Pr. PB13] and [Pr. PB15] by the vibration tough drive function is performed constantly. However,
the number of write times to the EEPROM is limited to once per hour.
• The vibration tough drive function does not reset [Pr. PB46 Machine resonance suppression filter 3], [Pr.
PB48 Machine resonance suppression filter 4], and [Pr. PB50 Machine resonance suppression filter 5].
• The vibration tough drive function does not detect a vibration of 100 Hz or less.
Содержание MELSERVO-J4 series
Страница 2: ......
Страница 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Страница 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Страница 645: ......