226
5 PARAMETERS
5.3 Software limit
5.3
Software limit
The limit stop with the software limit ([Pr. PT15] to [Pr. PT18]) is the same as the motion of the stroke end. Exceeding a setting
range will stop and servo-lock the shaft. This will be enabled at power-on and will be disabled in the velocity mode, torque
mode, and homing mode. Setting a same value to "Software limit +" and "Software limit -" will disable this function. Setting a
larger value to "Software limit -" than "Software limit +" will disable this function.
Current position
Travel
impossible
Inhibited range
Software limit
Movable range
Travel possible