26
2.
Set MELSOFT connection.
Project window
[Parameter]
[PLC Parameter]
[Built-in Ethernet Port Setting]
/
button
*1
*1
button can be used with the QnUDVCPU.
• For "Ethernet Conf.", drag and drop the "MELSOT Connection Module" from "Module List" to the left side on
the window. Select a protocol from "Protocol" depending on the target device.
• For "Open Setting"
(2) Writing to the CPU module
From the "Write to PLC" window, write the parameter settings to the CPU module.
[Online]
[Write to PLC]
After writing the parameters to the CPU module, power off and on or reset the CPU module to enable the
parameters.
Item
Setting
Protocol
Select "TCP" or "UDP" depending on the connected device.
Open System
Select "MELSOFT Connection".