360
5 POSITIONING CONTROL
5.17 Continuous Trajectory Control
Pass point skip function
This function stops positioning to executing point and executes positioning to next point, by setting a skip signal toward each
pass point for continuous trajectory control.
Setting data
■
Skip signal devices
A bit device (or a specified bit in a word device) can be used.
Refer to the following for the setting range of usable devices.
MELSEC iQ-R Motion controller Programming Manual (Common)
Precautions
• When an absolute circular interpolation or absolute helical interpolation is specified to since point since the skip signal
specified point, set the absolute linear interpolation between them. If it does not set, it may occur an error and stop.
• If a skip signal is inputted at the end point, a deceleration stop occurs at that point and the program is ended.
Program example
<K 0>
Axis 1
CPSTART2
Skip
Skip
ABS-2
Speed
Axis 2
Axis 1,
Axis 2,
Speed
ABS-2
Axis 1,
Axis 2,
Speed
CPEND
100000
Point 1
positioning
processing
200000
Skip signal
(M200)
M200
Servo program
start
V
10000
10000
200000
200000
Start accept
15000
t
No skip
Skip signal
Содержание MELSEC iQ-R16MTCPU