5 POSITIONING CONTROL
5.1 Basics of Positioning Control
259
5
Stop processing and restarting after stop
This section describes the stop processing after a stop cause is input during positioning and restarting after stop.
Stop processing
■
Stop processing methods
Stop processing during positioning by stop cause are as follows.
• Deceleration stop
Deceleration stop by "stop deceleration time" of parameter block.
• Rapid stop
Deceleration stop by "rapid stop deceleration time" of parameter block.
• Immediate stop
Stop without deceleration processing.
• Deceleration stop (individual)
Deceleration stop not using "stop deceleration time" of parameter block.
(1) During manual pulse generator operation, the deceleration time is "(Smoothing magnifi 1)
56.8 [ms]".
(2) During speed-torque control of speed control, the deceleration time is the deceleration time specified in the command
speed deceleration time.
Speed limit value
Stop cause
Operation speed
Stop
Real deceleration time
"Stop deceleration time" of
parameter block
Stop cause
Stop
Real deceleration time
"Rapid stop deceleration
time" of parameter block
Stop cause
Stop