28 FUNCTIONS
435
28
28
FUNCTIONS
This chapter describes the redundant functions and the functions that are different (modified or restricted) from those of the
process mode. Functions not described in this chapter are the same as those described in PART 2.
For the availability of the functions in the redundant system, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Startup)
Function
Description
Reference
Redundant function
Operation mode change
Switches the operation mode of the redundant system
between the backup mode for normal operation and the
separate mode for system maintenance while it is running.
Page 438 Operation
Mode Change
System switching
Switches the systems between the control system and the
standby system to continue operation of the redundant
system when a failure or an error occurs in the control
system. For debugging and maintenance purpose, users can
switch the systems at any desired timing.
Tracking transfer
Transfers the control data from the control system to the
standby system and maintains the consistency of the data in
the two systems to continue operation of the redundant
system when a failure or an error occurs in the control
system.
Memory copy from control system to
standby system
Transfers data such as parameters and programs in the CPU
module of the control system to the CPU module of the
standby system to maintain the consistency of the memory in
the two CPU modules.
Page 468 Memory Copy
from Control System to
Standby System
System consistency check
Checks whether the system configurations and files in the
CPU modules are the same between the control system and
the standby system when the redundant system is in backup
mode.
Page 475 System
Consistency Check
Program execution in both systems
Detects an error in the external device or network of the
systems (control system and standby system) by executing a
program that diagnoses external devices or networks of both
systems.
Page 479 Program
Execution in Both
Systems
Redundant function module
communication test
Checks a redundant function module for error when the
communications of the redundant function module are
unstable.
Содержание MELSEC iQ-R-R00CPU
Страница 2: ......
Страница 151: ...9 MONITOR FUNCTION 9 1 Real Time Monitor Function 149 9 MEMO ...
Страница 323: ...18 SEQUENCE SCAN SYNCHRONIZATION SAMPLING FUNCTION 321 18 MEMO ...
Страница 330: ...328 20 ROUTING SETTING 20 3 Precautions MEMO ...
Страница 423: ...26 BASIC CONCEPT 26 8 State Transition of the Redundant System 421 26 MEMO ...
Страница 524: ...522 30 MAINTENANCE AND INSPECTION FOR A REDUNDANT SYSTEM 30 1 Module Replacement in the Redundant System MEMO ...
Страница 1009: ...APPX Appendix 14 List of Available SQL Commands for CPU Module Database Access Function 1007 A MEMO ...
Страница 1014: ...1012 APPX Appendix 15 Added and Enhanced Functions MEMO ...
Страница 1027: ......