6 WIRING
6.7 Examples of Wiring for Various Uses
127
6
Digital switch
When DSW instructions are used
Examples of wiring for capturing values from a 4-digit digital switch to the data register D100 are given below.
For the instructions, refer to
MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks).
■
Example of program
■
Example of wiring
• Sink wiring
The example is the wiring for the input/output of the FX5UC-32MT/D.
• Source wiring
The example is the wiring for the input/output of the FX5UC-32MT/DSS.
*1 The grounding resistance should be 100
or less.
DSW
SM400
X10
Y10
D100
K1
COM X10 X11 X12 X13
X15
X14
X16 X17
COM0 Y10 Y11 Y12 Y13
Sink input
FX5UC-32MT/D
1
2
4
8
10
3
10
2
10
1
10
0
10
3
10
2
10
1
10
0
Transistor output (sink)
COM0
Fuse
24 V DC
*1
Digital
switch of
BCD
0.1 A 50 V
diode is
necessary.
Class D
grounding
COM0 X10 X11 X12 X13
X15
X14
X16 X17
+V0 Y10 Y11 Y12 Y13
Source input
FX5UC-32MT/DSS
1
2
4
8
10
3
10
2
10
1
10
0
10
3
10
2
10
1
10
0
Transistor output (source)
+V0
Fuse
24 V DC
*1
Digital
switch of
BCD
0.1 A 50 V
diode is
necessary.
Class D
grounding