692
8 APPLICATION INSTRUCTION
8.24 Clock Instruction
Subtracting clock data
TSUB(P)
These instructions subtract the time data stored in the device numbers starting from (s2) from the clock data stored in the
device numbers starting from (s1), and store the result to the device numbers starting from (d).
Setting data
■
Descriptions, ranges, and data types
■
Applicable devices
Processing details
• These instructions subtract the time data stored in the device numbers starting from (s2) from the clock data stored in the
device numbers starting from (s1), and store the result to the device numbers starting from (d).
Ladder diagram
Structured text
ENO:=TSUB(EN, s1, s2,d);
ENO:=TSUBP(EN, s1, s2,d);
FBD/LD
Operand
Description
Range
Data type
Data type (label)
(s1)
Head device number where the clock data that is subtracted is stored
16-bit signed binary
ANY16_ARRAY
(Number of elements: 3)
(s2)
Head device number where the subtracting time value (or clock data
value) is stored
16-bit signed binary
ANY16_ARRAY
(Number of elements: 3)
(d)
Head device number where the resultant clock data (or time value) is
stored
16-bit signed binary
ANY16_ARRAY
(Number of elements: 3)
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
X, Y, M, L, SM,
F, B, SB, S
T, ST, C, D, W,
SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(s1)
(s2)
(d)
(s1) (s2)
(d)
EN
ENO
d
s1
s2
(s1)
(s1)+1
(s1)+2
-
(s2)
(s2)+1
(s2)+2
(d)
(d)+1
(d)+2
(0 to 23)
(0 to 59)
(0 to 59)
hour
minute
second
(0 to 23)
(0 to 59)
(0 to 59)
hour
minute
second
(0 to 23)
(0 to 59)
(0 to 59)
hour
minute
second
Содержание MELSEC iQ-F FX5
Страница 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Страница 2: ......
Страница 17: ...15 CONTENTS ...
Страница 24: ...22 MEMO ...
Страница 25: ...23 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW 2 PRECAUTIONS ON PROGRAMMING ...
Страница 126: ...124 6 SEQUENCE INSTRUCTIONS 6 3 Output Instructions Operation error There is no operation error ...
Страница 132: ...130 6 SEQUENCE INSTRUCTIONS 6 3 Output Instructions Operation error There is no operation error ...
Страница 140: ...138 6 SEQUENCE INSTRUCTIONS 6 3 Output Instructions Operation error There is no operation error ...
Страница 191: ...7 BASIC INSTRUCTIONS 7 2 Arithmetic Operation Instructions 189 7 Operation error There is no operation error ...
Страница 202: ...200 7 BASIC INSTRUCTIONS 7 2 Arithmetic Operation Instructions Operation error There is no operation error ...
Страница 278: ...276 7 BASIC INSTRUCTIONS 7 4 Bit Processing Instructions Operation error There is no operation error ...
Страница 280: ...278 7 BASIC INSTRUCTIONS 7 4 Bit Processing Instructions Operation error There is no operation error ...
Страница 915: ...18 TYPE CONVERSION FUNCTIONS 18 13 Converting DWORD to WORD 913 18 Operation error There is no operation error ...
Страница 917: ...18 TYPE CONVERSION FUNCTIONS 18 14 Converting DWORD to INT 915 18 Operation error There is no operation error ...
Страница 932: ...930 18 TYPE CONVERSION FUNCTIONS 18 26 Converting DINT to WORD Operation error There is no operation error ...
Страница 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Страница 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Страница 1107: ...I 1105 MEMO ...
Страница 1111: ......