6 CC-Link IE Field Network FUNCTION
6.2 Transient Transmission
51
6
6.2
Transient Transmission
This function communicates with other stations during execution of MELSEC data link functions.
Transient transmission applies to communication of low-frequency reading and writing data and large-sized data.
Communication within the same network
Transient transmission to other stations is performed by MELSEC data link functions.
Access to devices on another station
Devices of other stations are accessed directly by a user program.
Connected network modules and control CPU modules can be accessed.
■
Function list
For details on MELSEC data link functions, refer to the following manual.
MELIPC MI5000 Series Programming Manual (VxWorks)
■
When accessing another CPU module in a multiple CPU system
When accessing another CPU in a multiple CPU system on another station by transient transmission, setting a logical number
is required. (Logical station number is a logical station number that can be used in a user program.)
Specify a logical station number in MI Configurator or a user program.
For the specification method in MI Configurator, refer to the following section.
Page 191 Access target settings
For the specification method in a user program, refer to the following manual.
MELIPC MI5000 Series Programming Manual (VxWorks)
Function name
Description
mdDevRstEx
Resets bit devices.
mdDevSetEx
Sets bit devices.
mdRandREx
Reads data by specifying a device type and a range to be read.
mdRandWEx
Writes data by specifying a device type and a range to be written.
mdReceiveEx
Reads data from devices in a batch.
mdSendEx
Writes data to devices in a batch.
mdRemBufReadEx
Reads data from the buffer memory of a remote device station on CC-Link IE Field Network.
mdRemBufWriteEx
Writes data to the buffer memory of a remote device station on CC-Link IE Field Network.
Содержание MELIPC MI5000 Series
Страница 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Страница 2: ......
Страница 18: ...16 MEMO ...
Страница 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Страница 42: ...40 5 iQSS FUNCTION MEMO ...
Страница 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Страница 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Страница 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Страница 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Страница 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Страница 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Страница 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Страница 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Страница 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Страница 177: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 175 17 External device connection applicable settings Window ...
Страница 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Страница 315: ...I 313 MEMO ...
Страница 319: ......