15 OS LINKING FUNCTIONS
15.1 Virtual Ethernet Function
15
OS LINKING FUNCTIONS
This chapter explains the OS linking function of this product.
15.1
Virtual Ethernet Function
This function connects the Windows part and VxWorks part of this product using a virtual network.
By using this function, the VxWorks part can be monitored and tested from MI Configurator installed on the Windows part.
Furthermore, this function is used as a communication route of the Windows part and VxWorks part, such as a connection
with MELSOFT products and GT SoftGOT.
For the connection method of MELSOFT products and GOT, refer to the following page.
Page 145 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION
Connection of Windows part and VxWorks part
The sections are connected by the following IP addresses configured to virtual Ethernet.
• Windows part: 172.16.0.2
• VxWorks part: 172.16.0.1
Precautions
• By using this function, the connection is handled as a connection of MELSOFT products when MI Configurator installed on
the Windows part is connected to the VxWorks part. If another MELSOFT product is connected to this product, add the
number of connections of the virtual Ethernet and Ethernet port (CH 1) in the "External Device Configuration" of "Basic
Setting".
• Do not change the virtual Ethernet (Wind River Virtual Network Adapter) settings. If the settings are changed,
communication between the Windows part and VxWorks part using virtual Ethernet is no longer possible.
(1) VxWorks part
(2) Windows part
MI Configurator
(1)
(2)
Содержание MELIPC MI5000 Series
Страница 1: ...MELIPC MI5000 Series User s Manual Application MI5122 VW ...
Страница 2: ......
Страница 18: ...16 MEMO ...
Страница 22: ...20 1 DIAGNOSTIC AND MAINTENANCE FUNCTIONS 1 1 Watchdog Timer WDT Function MEMO ...
Страница 42: ...40 5 iQSS FUNCTION MEMO ...
Страница 146: ...144 11 SECURITY FUNCTION 11 3 IP Filter Function MEMO ...
Страница 148: ...146 12 MELSOFT PRODUCT AND GOT CONNECTION FUNCTION 12 1 Connection Method MEMO ...
Страница 150: ...148 13 SYSTEM COUNT FUNCTION MEMO ...
Страница 152: ...150 14 TIMER EVENT FUNCTION MEMO ...
Страница 160: ...158 15 OS LINKING FUNCTIONS 15 3 Inter OS Event Notification Function MEMO ...
Страница 162: ...160 16 SERIAL INTERFACE SWITCHING FUNCTION MEMO ...
Страница 165: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 163 17 Operation related setting Window ...
Страница 170: ...168 17 BASIC PARAMETERS 17 1 Basic Parameter List RAS setting Window ...
Страница 174: ...172 17 BASIC PARAMETERS 17 1 Basic Parameter List External device connection settings Window ...
Страница 177: ...17 BASIC PARAMETERS 17 1 Basic Parameter List 175 17 External device connection applicable settings Window ...
Страница 313: ...APPX Appendix 10 List of VxWorks Components 311 A MEMO ...
Страница 315: ...I 313 MEMO ...
Страница 319: ......