2Unpacking to Installation
Installation
2-13
Table 2-4:Magnitude of each reaction force
Secure the maintenance space necessary at rear for connection of the machine
cable and for replacement of the backup battery. For the dimensions of the
maintenance space, refer to "Outside dimensions/Operating range diagram" in the
Standard Specifications Manual.
Do not install the robot arm in areas where direct sunlight is present or heat is
generated from lighting.
The skin temperature of the robot arm may rise, and the error may occur.
Item
Unit
Value
RH-3CRH
Tilt moment
: M
L
N
・
m
220
Torsional moment
: M
T
N
・
m
180
Horizontal direction translation force
: F
H
N
820
Vertical direction translation force : F
V
N
320
RH-6CRH6020
Tilt moment
: M
L
N
・
m
410
Torsional moment
: M
T
N
・
m
260
Horizontal direction translation force
: F
H
N
800
Vertical direction translation force : F
V
N
640
RH-6CRH7020
Tilt moment
: M
L
N
・
m
500
Torsional moment
: M
T
N
・
m
370
Horizontal direction translation force
: F
H
N
960
Vertical direction translation force : F
V
N
670
CAUTION