-68-
(10) Specifying the mode switching judgment value (P_FsSwf0/P_FsSwf1, FSSWF0#)
Set the threshold used for the switching judgment for "speed priority mode" and "force priority
mode" when the speed command value is set.
When the force control is enabled, the speed priority mode and force priority mode can be
switched based on the force specified in each axis.
<Force priority mode>
Data from the force sensor is used to control the robot until the force specified with the force
specification value is reached.
The robot moves in the direction which satisfies the force specification value by following the
axis direction for which force control is specified.
The offset speed for force control is limited to the speed command value or below.
<Speed priority mode>
The robot is controlled so that the speed specified with the speed command value is reached.
The robot moves in the direction which satisfies the force specification value by following the
axis direction for which force control is specified.
P_FsSwf0 / P_FsSwf1 = (
△
,
△
,
△
,
△
,
△
,
△
,
0,0)(0,0)
△
= - (force sensor tolerance value) to + (force sensor tolerance value)
X, Y, Z · · · [N]
A, B, C · · · [N·m]
P_FsFCd0 = (0, 0, 1.0, 0, 0, 0, 0, 0)(0, 0)
· · · Apply +10 N to tool Z-direction when
switched to force priority mode
P_FsSpd0 = (0, 0, 10, 0, 0, 0, 0, 0)(0, 0)
· · ·
Set the speed of Z-direction to 10 mm/s
P_FsSwf0 = (0, 0, 5, 0, 0, 0, 0, 0)(0, 0)
· · ·
Switch to force priority mode when +5 N is
applied to Z-direction
Operate in 10 [mm/s] until the robot contacts the target in -Z-direction with 5 [N], and
apply 10 [N] after contact.
Program example
Moves in 10 mm/s
Contact in 10 mm/s until the
force applied reaches 5 N
Apply 10 N when the force
applied reaches 5 N
10 mm/s
10 mm/s
10N
Up to
5 N
Содержание MELFA BFP-A3614
Страница 1: ...Mitsubishi Industrial Robot Robot Seminar Textbook Force Sensor Application BFP A3614 ...
Страница 2: ......
Страница 8: ... Revision History Print Date Instruction Manual No Revision content 2018 07 31 BFP A3614 First print ...
Страница 33: ... 22 b CR800 R controller CN1 connector CR800 R controller front To OPT1 connector CPU module SSCNET III cable ...
Страница 34: ... 23 2 F series a CR750 D controller ...
Страница 35: ... 24 b CR751 D controller ...
Страница 36: ... 25 c CR750 Q CR751 Q controller CPU module ...
Страница 75: ... 64 MEMO Please use this page for your memo ...
Страница 95: ... 84 MEMO Please use this page for your memo ...
Страница 103: ... 92 MEMO Please use this page for your memo ...
Страница 111: ... 100 MEMO Please use this page for your memo ...
Страница 119: ... 108 MEMO Please use this page for your memo ...
Страница 123: ... 112 MEMO Please use this page for your memo ...
Страница 129: ... 118 MEMO Please use this page for your memo ...
Страница 133: ... 122 MEMO Please use this page for your memo ...
Страница 137: ... 126 MEMO Please use this page for your memo ...
Страница 143: ... 132 MEMO Please use this page for your memo ...
Страница 149: ... 138 MEMO Please use this page for your memo ...
Страница 153: ... 142 MEMO Please use this page for your memo ...
Страница 159: ... 148 MEMO Please use this page for your memo ...
Страница 171: ... 160 MEMO Please use this page for your memo ...
Страница 183: ... 172 MEMO Please use this page for your memo ...
Страница 191: ... 180 MEMO Please use this page for your memo ...
Страница 211: ......