3. Setting
51
3.15. Initializing Related Items by Changing Settings
When a setting value is changed, the related setting items and measurement data (maximum/minimum values) will return to
the default settings. Refer to the following list.
Setting item to be changed
Initialized item
Menu 1
Menu 2
Menu 5 Menu 6
Menu 8
C
hange of
opt
ional
pl
ug
-i
n
m
odul
e
P
has
e w
ir
e
s
y
s
te
m
(*1
)
V
T
/
di
re
c
t v
ol
tage
CT current
M
O
DB
US
®
T
CP
De
fa
u
lt
gat
ew
ay
e
x
is
te
n
c
e
C
om
m
uni
c
a
ti
on R
e
s
et
U
pper
/l
ow
er
l
im
it
al
ar
m
i
te
m
A
nal
og
out
pu
t i
tem
T
ar
get
f
or
c
ount
ing
O
per
at
ion
tim
e
S
et
ti
ng
of
I
E
C
m
ode
C
T
s
e
c
ondar
y
c
ur
rent
C
T
p
ri
m
a
ry
c
ur
rent
S
et
ti
ng
it
em
Menu 1
Phase wire system
Display pattern
●
VT/direct voltage
○
Menu2
MODBUS®TCP Default gateway
●
Menu 3
Current scale
●
Voltage scale
●
●
Power scale
●
●
●
Reactive power scale
●
●
●
Menu 5
Upper/lower limit alarm item
●
Upper/lower limit alarm value
●
●
Menu 6
Analog output item
●
Maximum current scale
●
●
●
Maximum current demand scale
●
●
●
Maximum voltage scale
●
●
●
Maximum active power scale
●
●
●
●
Active power single deflection/
double deflection
●
●
Maximum reactive power scale
●
●
●
●
Power factor
-0.5 to 1 to 0.5
/
-0 to 1 to 0
●
●
Menu 7
Control setting for switching Periodic
Active energy time segments
●
Setting of rolling demand digital input
time period
●
Menu 8 Threshold for counting Operation time
●
M
eas
ur
em
ent
dat
a
Current Maximum/minimum value
●
●
●
Current demand Maximum/minimum value
●
●
●
Voltage Maximum/minimum value
●
●
Active power Maximum/minimum value
●
●
●
●
Reactive power Maximum/minimum value
●
●
●
●
●
Apparent power Maximum/minimum value
●
●
●
●
●
Power factor Maximum/minimum value
●
●
●
●
●
Frequency Maximum/minimum value
●
Harmonic current Maximum value
●
●
●
Harmonic voltage Maximum value
●
●
Rolling demand(DW,Dvar,DVA)
Maximum
value
●
●
●
●
●
Communication optional plug-in module reset (*2)
●
●
●
●
●:
The setting value will be reset to the default value.
○:
The setting will be reset to the value corresponding to the phase wire system.
*1: The settings will not return to the default values when the setting is switched only between “1N2 display” and “1N3 display” in
the 1-phase 3-wire setting.
*2: Communication optional plug-in module is reset.
Содержание ME96SSRA-MB
Страница 88: ...87 Installation 1 Dimensions ME96SSRA MB Optional Plug in Module ME 4210 SS96 ME 0040C SS96 ME 0052 SS96 ...
Страница 89: ...88 Installation 1 Dimensions Optional Plug in Module ME 0000MT SS96 Optional Plug in Module ME 0000BU SS96 ...
Страница 98: ...97 Installation 4 Wiring Diagram Optional Plug in Module ME 0000MT SS96 Optional Plug in Module ME 0000BU SS96 ...