1
Safety Precautions
• Before instralling this unit,make sure you read all the “Safety Precautions”.
• This manual describes the installation of LM-AP and wiring to the outdoor unit.
• Please look at the installation manual of an air-conditioning unit about the installation method of an air-conditioning unit.
• The “Safety Precautions” provide very important points regarding safety. Make sure you follow them.
Symbols and Terms
Statements identify condition or practices that could result in personal injury or loss of life.
Statements identify condition or practices that could result in damage to the unit or other
property.
Symbols used in the illustrations
: Indicates a part which must be grounded.
: Indicates that the main switch must be turned off before servicing.
(This symbol is displayed on the main unit label.) <Color: Blue>
: Beware of electric shock.(This symbol is displayed on the main unit label) <Color: Yellow>
: Please pay attention to electric shock fully because this is not Safety Extra Low-Voltage (SELV)
circuit.
And at servicing,please shut down the power supply for LM-AP.
WARNING
WARNING
CAUTION
Ask your dealer or technical representative to install.
Any deficiency cased by your own installation may result in an
electric shock and fire.
Ensure that installation work is done correctly following
that installation manual.
Any deficiency caused by installation may result in an electric
shock or fire.
Install in a plase which is strong enough to withstand the
weight of the unit
Any lack of the strength may cause the unit to fall down,
resulting in a personal injury.
Any deficiency caused by installation may result in an electric
shock, fire or incorrect operation.
All electrical work must be performed by a licenced
technician, according to local regulations and the
instructions given in this manual.
Any lack of electric circuit or any deficiency caused by
installation may result in an electric shock or fire.
Wire and connect using the desired cables securely so
that any external force from the cable is imparted to the
terminal connections.
Imperfect connection and fixed may result in heading or fire.
Securely install the cover (panel) of the LM-AP.
If the cover (panel) is not installed properly, dust or water may
enter the unit and fire or electric shock may result.
Never modify or repair the unit by yourself.
Any deficiency caused by your modification or repair may
result in an electric shock or fire. Consult with your distributor
for repair.
Do not move and re-install the unit yourself.
Any deficiency caused by installation may result in an electric
shock or fire. Ask your distributor or special vender for moving
and installation.
Make sure that the unit is powered by dedicated line.
Other appearance connected to the same line could cause an
overload.
Make sure that there is a main power switch.
A ready accessible breaker for power source line helps
reduce the risk of electric shocks.Installation of a breaker is
mandatory in same areas.
If it is assumed that moisture advances into the unit,
such as the time of rainy weather, do not do check or
work of an electric circuit.
It may become the cause of damage of a fire and the unit by
an electric shock or corrosion.
• After reading this installation manual, keep it in a place where the final user can see it anytime he or she wants to it.
When someone moves, repairs or uses the LM-AP, make sure that this manual is forwarded to the final user.