2 COMMUNICATION WITH A PERSONAL COMPUTER (GT DESIGNER3, DATA TRANSFER TOOL)
2.1 USB Connection
15
2
How to install the USB driver
Follow the procedure below.
1.
Connect the A type connector of the USB cable to the USB port on the PC side.
2.
Connect the Mini-B side of the USB cable to the USB interface of the LE7-40GU.
3.
Switch on the LE7-40GU power supply.
4.
The USB driver is installed automatically to the PC only when it is connected for the first time.
When the USB driver of other products is installed, the confirmation message for overwriting the USB driver
file (windrvr6.sys) may appear. If a new file already exists, click the [No] button and do not overwrite the file.
When the file is overwritten, the USB communication of GT Designer3 and the LE7-40GU may not be properly
executed.
Precautions for using a USB cable
To transfer the data by connecting the personal computer and the LE7-40GU using a USB cable, do not set the resume
function, the suspending function, the power saving function, or the standby mode of the personal computer. For the details of
the resume function, the suspending function, the power saving function or the standby mode, refer to the manual of the
personal computer or the Help of Windows.
If the USB cable is removed or the LE7-40GU is reset or powered off/on, the communication may not be recovered from an
error. In this case, perform either of the following operations.
• Checking if the personal computer recognizes the USB.
Check that [MITSUBISHI GOT2000 USB Controller] is displayed in [USB (Universal Serial Bus) Controller] in the device
manager.
• Restart the LE7-40GU.
Remove the USB cable from the LE7-40GU and power off the LE7-40GU. After the LE7-40GU is powered off, restart the LE7-
40GU and connect a cable to communicate again.
Checking the file overwrite
Copy source: C:\...........\windrvr6.sys
Copy destination: C:\.................\windrvr6.sys
A file newer than the source file exists in the copy destination.
Are you sure you want to overwrite the new file?
Not all (A)
No (N)
Yes (Y)
Содержание LE7-40GU
Страница 1: ...LE7 40GU INSTRUCTION MANUAL Communication ...
Страница 2: ......
Страница 10: ...8 TRADEMARKS 150 ...
Страница 11: ...9 CONTENTS ...
Страница 37: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 35 3 ...
Страница 38: ...36 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Страница 39: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 37 3 ...
Страница 40: ...38 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Страница 57: ...4 SLMP COMMUNICATION 4 3 Reference Program 55 4 Program example ...
Страница 58: ...56 4 SLMP COMMUNICATION 4 3 Reference Program ...
Страница 59: ...4 SLMP COMMUNICATION 4 3 Reference Program 57 4 ...
Страница 60: ...58 4 SLMP COMMUNICATION 4 3 Reference Program ...
Страница 61: ...4 SLMP COMMUNICATION 4 3 Reference Program 59 4 ...
Страница 82: ...80 5 MODBUS TCP SLAVE 5 3 Reference Program Program example ...
Страница 83: ...5 MODBUS TCP SLAVE 5 3 Reference Program 81 5 ...
Страница 84: ...82 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Страница 85: ...5 MODBUS TCP SLAVE 5 3 Reference Program 83 5 ...
Страница 86: ...84 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Страница 110: ...108 6 N N NETWORK 6 4 Reference Program Program example ...
Страница 111: ...6 N N NETWORK 6 4 Reference Program 109 6 ...
Страница 112: ...110 6 N N NETWORK 6 4 Reference Program ...
Страница 147: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 145 7 Function code H03 Read holding register ...
Страница 149: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 147 7 ...
Страница 153: ......