
22. ETHERNET CONNECTION
22.3 GOT Side Settings
22 - 15
20
DIRE
CT
CONNECTION T
O
CPU
21
COMP
U
T
E
R
LINK
CONNECTION
22
ETHE
R
N
E
T
CONNE
C
T
ION
23
CC-L
ink
CON
NE
CT
ION
(V
ia
G
4)
24
INV
E
R
T
ER
CONNECTION
25
SER
VO
A
M
PLI
F
IE
R
C
O
NNECTION
26
ROBOT
CONTROLLE
R
CONNECTION
27
CNC CONNE
C
T
ION
POINT
POINT
POINT
(1) Example of [Detail setting].
For examples of [Detail Setting], refer to the
following.
(2) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For the details on the Utility, refer to the following
manual.
12. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(3) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
22.3.3 Ethernet setting
*1
Select one of the following [Controller Type].
• Built-in Ethernet port (hereafter CPU): RCPU, RnMTCPU,
RnPCPU
• C Controller module (MELSEC iQ-R series): RnCCPU
• Built-in Ethernet port (MELSEC iQ-F series): FX5CPU
• Connection to Built-in Ethernet port QCPU: QnUD(P)V/
QnUDEH
• Connection to Built-in Ethernet port Q170MCPU, Q172/
Q173DCPU: QnUDE(H)
• C Controller module (Q Series): QnD(H)CCPU
• Connection to Built-in Ethernet port LCPU: LCPU
• Ethernet module (NZ2GF-ETB): NZ2GF-ETB
• Q17nNCCPU: Q17nNC
• Ethernet module (MELSEC iQ-R Series): RJ71EN71
• Ethernet module (Q, L Series): QJ71E71/LJ71E71
• Ethernet module (QnA Series): AJ71QE71
• Ethernet module (A Series): AJ71E71
• Ethernet module (FX Series): FX
• Built-in Ethernet port FXCPU: FX
For the applicable Ethernet module, refer to the following.
*2
Set only when selecting "AJ71E71" in [Controller Type].
When other than [AJ71E71] is selected, the port No. is as
follows.
• [RCPU], [RnCCPU], [QnUDE(H)]: 5006 (fixed)
• [FX5CPU]: 5562 (fixed)
• [RJ71EN71], [Q17nNC], [QJ71E71], [AJ71QE71]: 5001
(fixed)
• [FX]: 5551 (When using FX
3U
-ENET-L)
5556 (When using FX
3U
-ENET-ADP)
When using built-in Ethernet port FXCPU: 5556
*3
When selecting the FX in [Controller Type], the
communication type is the TCP (fixed).
*4
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
22.3.2 Communication detail settings
*5
When selecting other than RCPU and RJ71EN71, the range
is 1 to 64.
POINT
POINT
POINT
(1) Example of [Ethernet]
For examples of [Ethernet], refer to the following.
(2) Parameter reflection function of MELSOFT
Navigator
(a) The color of the cells for the items which are
reflected to GT Designer3 from MELSOFT
Navigator changes to green.Set items, which
are displayed in green cells, from the
MELSOFT Navigator.
(b) When the settings of N/W No., PLC No., type
or IP address are reflected to the parameter
from the MELSOFT Navigator, those settings
are added. Items set in advance are not
deleted. However, if the combination of the N/
W No. and the PLC No. or the IP address
overlaps, the item set in advance is
overwritten.
Item
Description
Range
Host
The host is displayed. (The host
is indicated with an asterisk (*).)
-
N/W No.
Set the network No. of the
connected Ethernet module.
(Default: blank)
1 to 239
PLC No.
*4
Set the station No. of the
connected Ethernet module.
(Default: blank)
1 to 120
*5
Type
*1
Set the type of the connected
Ethernet module.
(Default: QJ71E71/LJ71E71)
RCPU,
RnCCPU,
FX5CPU,
QnUD(P)V/
QnUDEH,
QnD(H)CCPU,
LCPU,
Q17nNC,
RJ71EN71,
QJ71E71/
LJ71E71,
AJ71QE71,
AJ71E71,
FX,
NZ2GF-ETB
IP address
Set the IP address of the
connected Ethernet module.
(Default: blank)
0.0.0.0 to
255.255.255.255
Port No.
*2
Set the port No. of the connected
Ethernet module.
(Default: 5001)
1024 to 65534
Communication
*3
UDP
UDP,
TCP
Содержание GT16
Страница 1: ......
Страница 2: ......
Страница 46: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 54: ...2 8 2 SYSTEM CONFIGURATION 2 2 System Equipment ...
Страница 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Страница 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Страница 102: ...6 30 6 OPTION 6 7 Connector Conversion Box ...
Страница 106: ...7 4 7 INSTALLATION 7 1 Installing Procedure ...
Страница 110: ...8 4 8 COMMUNICATION CABLE 8 1 Overview of Communication Cable ...
Страница 130: ...9 20 9 HANDLING OF POWER WIRING AND SWITCH 9 4 Switch Wiring ...
Страница 142: ...10 12 10 UTILITY FUNCTION 10 3 Utility Display ...
Страница 184: ...11 42 11 DISPLAY AND OPERATION SETTINGS GOT SET UP 11 4 Maintenance Function ...
Страница 202: ...12 18 12 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 12 3 Ethernet Setting ...
Страница 226: ...13 24 13 DEBUG 13 3 Memory Data Control ...
Страница 248: ...14 22 14 SELF CHECK 14 2 Batch Self Check ...
Страница 350: ...15 102 15 DATA CONTROL 15 3 OS Project Information ...
Страница 410: ...19 22 19 TROUBLESHOOTING 19 2 Error Message and System Alarm ...
Страница 418: ...App 8 APPENDICES Appendix 3 Transportation Precautions ...
Страница 422: ...REVISIONS 4 ...
Страница 425: ......
Страница 426: ......
Страница 427: ......
Страница 428: ......
Страница 470: ......
Страница 510: ...21 22 21 COMPUTER LINK CONNECTION 21 6 Precautions ...
Страница 568: ...22 58 22 ETHERNET CONNECTION 22 5 Precautions ...
Страница 584: ......
Страница 626: ...25 14 25 SERVO AMPLIFIER CONNECTION 25 7 Precautions ...
Страница 632: ...26 6 26 ROBOT CONTROLLER CONNECTION 26 6 Precautions ...
Страница 647: ...MULTIPLE GOT CONNECTIONS 29 GOT MULTI DROP CONNECTION 29 1 ...
Страница 648: ......
Страница 659: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Страница 660: ......
Страница 675: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Страница 676: ......
Страница 742: ...31 66 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Страница 744: ......
Страница 766: ...32 22 32 CONNECTION TO IAI ROBOT CONTROLLER 32 7 Precautions ...
Страница 802: ...34 10 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Страница 834: ...36 18 36 CONNECTION TO KOYO EI PLC 36 6 Device Range that Can Be Set ...
Страница 858: ...38 12 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Страница 868: ...39 10 39 CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER 39 7 Precautions ...
Страница 902: ...42 6 42 CONNECTION TO TOSHIBA MACHINE PLC 42 6 Device Range that Can Be Set ...
Страница 908: ...43 6 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Страница 970: ...48 12 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Страница 1052: ...52 26 52 CONNECTION TO AZBIL CONTROL EQUIPMENT 52 7 Precautions ...
Страница 1102: ...55 14 55 CONNECTION TO GE PLC 55 7 Precautions ...
Страница 1114: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Страница 1128: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Страница 1130: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Страница 1131: ...MICROCOMPUTER CONNECTION 61 MICROCOMPUTER CONNECTION SERIAL 61 1 62 MICROCOMPUTER CONNECTION ETHERNET 62 1 ...
Страница 1132: ......
Страница 1270: ...62 68 62 MICROCOMPUTER CONNECTION ETHERNET 62 8 Precautions ...
Страница 1271: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Страница 1272: ......
Страница 1292: ...64 12 64 MODBUS R TCP CONNECTION 64 7 Precautions ...
Страница 1293: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Страница 1294: ......
Страница 1298: ...65 4 65 VNC R SERVER CONNECTION 65 4 Setting in Personal Computer ...
Страница 1302: ...REVISIONS 4 ...
Страница 1305: ......
Страница 1306: ......