2 - 8
2. DEVICE RANGE THAT CAN BE SET
2.1 MELSEC iQ-R, RnMT
2.1 MELSEC iQ-R, RnMT
The table below shows the device ranges in [MELSEC iQ-
R, RnMT] as the controller type.
*1
For the maximum number of devices when an extended
SRAM cassette is installed, refer to the following.
MELSEC iQ-R CPU Module User's Manual
(Application)
*2
Monitoring or writing is not possible in the continuous device
designation mode.
*3
Only the intelligent function module on the station connected
to GOT can be specified.
Set the buffer memory within the address range of the buffer
memory existing in the intelligent function module.
*4
For monitoring the multiple CPU high speed transmission
memory, the CPU buffer memory access device (HG) for
RCPU is monitored.
The CPU buffer memory access device (G) is not monitored.
*5
Only reading is possible.
Device name
Setting range
Device No.
representation
B
it device
Input (X)
X0 to X3FFF
Hexadecimal
number
Output (Y)
Y0 to Y3FFF
Internal relay (M)
*1
M0 to M161882111
Decimal
number
Latch relay (L)
L0 to L32767
Step relay (S)
*5
S0 to S16383
Annunciator (F)
F0 to F131071
Link relay (B)
*1
B0 to B9A61FFF
Hexadecimal
number
Timer
*1
Contact (TT)
TT0 to TT8993439
Decimal
number
Coil (TC)
TC0 to TC8993439
Long timer
*1*2
Contact (LTT) LTT0 to LTT2529407
Coil (LTC)
LTC0 to LTC2529407
Counter
*1
Contact (CT)
CT0 to CT8993439
Coil (CC)
CC0 to CC8993439
Long
counter
*1
Contact
(LCT)
LCT0 to LCT4761215
Coil (LCC)
LCC0 to LCC4761215
Special relay (SM)
SM0 to SM4095
Retentive
timer
*1
Contact (SS)
SS0 to SS8993439
Coil (SC)
SC0 to SC8993439
Long
retentive
timer
*1*2
Contact
(LSS)
LSS0 to LSS2529407
Coil (LSC)
LSC0 to LSC2529407
SFC block (BL)
BL0 to BL319
Step relay (block)(BLS)
BLS0 to BLS511
Link special relay (SB)
*1
SB0 to SB9A61FFF
Hexadecimal
number
Remote input (RX)
RX0 to RX3FFF
Remote output (RY)
RY0 to RY3FFF
Link relay (LB)
LB0 to LB7FFF
Bit-specified word device
(Except the timer, counter,
retentive timer, and index
register (Z))
Setting range of each
word device
-
Wo
rd
d
ev
ic
e
Data register (D)
*1
D0 to D10117631
Decimal
number
Special data register (SD)
SD0 to SD4095
Link register (W)
*1
W0 to W9A61FF
Hexadecimal
number
Timer
(current value) (TN)
*1
TN0 to TN8993439
Decimal
number
Counter
(current value) (CN)
*1
CN0 to CN8993439
Retentive timer
(current value) (SN)
*1
SN0 to SN8993439
Link special register (SW)
*1
SW0 to SW9A61FF
Hexadecimal
number
W
o
rd device
File register (R)
R0 to R32767
Decimal
number
Extension
file register
(ER)
Block
0 to 255
Device
ER0 to ER32767
Extension file register
(ZR)
*1
ZR0 to ZR10027007
Index register (16 bits) (Z)
Z0 to Z23
Buffer memory
(Intelligent function module)
(G)
*3
G0 to G268435455
Ww
Ww0 to Ww1FFF
Hexadecimal
number
Wr
Wr0 to Wr1FFF
Multiple CPU high speed
transmission memory
(U3E0)
*4
U3E000000 to
U3E012287
Decimal
number
Multiple CPU high speed
transmission memory
(U3E1)
*4
U3E100000 to
U3E112287
Multiple CPU high speed
transmission memory
(U3E2)
*4
U3E200000 to
U3E212287
Multiple CPU high speed
transmission memory
(U3E3)
*4
U3E300000 to
U3E312287
Motion device (#)
#0 to #108287
Word-specified bit devices
(except timer, long timer,
counter, long counter,
retentive timer, and long
retentive timer)
Setting range of each
bit device
-
Dou
b
le-wo
rd device
Long timer
(current value) (LTN)
*1*2
LTN0 to LTN2529407
Decimal
number
Long counter
(current value) (LCN)
*1
LCN0 to LCN4761215
Long retentive timer
(current value) (LSN)
*1*2
LSN0 to LSN2529407
Index register (32 bits)
(ZZ)
*2
ZZ0 to ZZ22
Index register (32 bits) (LZ) LZ0 to LZ11
Device name
Setting range
Device No.
representation
Содержание GT15
Страница 2: ......
Страница 34: ...A 32 ...
Страница 92: ......
Страница 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Страница 134: ...3 24 3 ACCESS RANGE FOR MONITORING 3 7 Connection to the Head Module of CC Link IE Field Network System ...
Страница 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Страница 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Страница 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Страница 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Страница 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Страница 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Страница 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Страница 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Страница 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Страница 510: ......
Страница 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Страница 668: ......
Страница 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Страница 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Страница 714: ......
Страница 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Страница 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Страница 762: ......
Страница 860: ...REVISIONS 4 ...
Страница 863: ......