53. CONNECTION TO RKC TEMPERATURE CONTROLLER
53.5 Temperature Controller Side Setting
53 - 45
53.5.15 Connecting to X-TIO Module
Communication settings
Make the communication settings of the temperature
controller.
*1
Adjust the settings with GOT settings.
*2
When the setting value is set to 0, a communication is not
made.
Setting DIP switches
Make the settings of transmission speed, data bit
configuration, communication protocol
Unit address settings
Set the unit address using the rotary switch (address
setting switch).
Data interval extension time settings
Set the data interval extension time as the following
procedure.
1.
Turn the power of the module OFF.
2.
Set the DIP switch 4 and 6 to "ON" and 5 to "OFF".
3.
Set the data interval extension time using the rotary
switch (address setting switch).
The setting method is the same as that of the module
address.
4.
Turn the power of the module ON.
The FAIL/RUN lamp lights in green and the set time
becomes valid.
5.
Turn the power of the module OFF again and set the
DIP switches and rotary switch to the original position.
53.5.16 Connecting to SB Series
Communication settings
*1
When the setting value is set to 0, a communication is not
made.
*2
Adjust the settings with GOT settings.
*3
Set the maximum time from the sending of the last character
stop bit from the GOT side until the switching of the GOT
side to the receiving status (until the temperature controller
becomes ready to send). Set as necessary.
Item
Setting range
Communication speed
*1
9600bps, 19200bps, 38400bps
Communication protocol 1
MODBUS
Data bit configuration
Data bit: 8bits, Parity: None
Data bit: 8bits, Parity: Even
Data bit: 8bits, Parity: Odd
Stop bit: 1bit (fixed)
Module address
*2
1 to 99
Internal data bus terminating
resistor
When combining the module, turn ON the
internal data bus terminating resistor at both
ends of the module.
Data interval extension time 0 to 99ms
Item
Set value
Switch No.
1
2
3
4
5
6
7
8
Communicati
on speed
9600bps
ON OFF
19200bps
OFF ON
38400bps
ON ON
Data bit
configuration
Data bit: 8bits,
Parity: None
ON OFF OFF
Data bit: 8bits,
Parity: Even
ON OFF ON
Data bit: 8bits,
Parity: Odd
ON
ON ON
Communicati
on protocol
MODBUS
ON
Internal data
bus
termination
resistor
setting
OFF
OFF
ON
ON
Data interval
extension
time
0 to 99ms
ON OFF ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
Dip switch
ON
OFF
Item
Setting range
*1
Communication protocol
1: MODBUS
Device address
(Slave address)
*1
1 to 99
Communication speed
*2
2: 9600bps
3: 19200bps
Data bit configuration
Refer to
Interval time
*3
0 to 250
5
4
3
2
1
0
9 8 7
6
5
5
4
3
2
1
0
9 8 7
6
5
FAIL/RUN
RX/TX
EVENT1
EVENT2
EVENT3
EVTNT4
5
4
3
2
1
0
9 8 7
6
5
5
4
3
2
1
0
9 8 7
6
5
Upper digit setting
(Set value x10)
Lower digit setting
(Set value x1)
Rotary switch
(Address setting switch)
Содержание GT14
Страница 1: ......
Страница 2: ......
Страница 34: ...A 32 ...
Страница 46: ...1 4 1 OVERVIEW 1 1 Features ...
Страница 60: ...3 6 3 SPECIFICATIONS 3 4 Battery specifications ...
Страница 72: ...5 8 5 UL cUL STANDARDS AND EMC DIRECTIVE 5 2 EMC Directive ...
Страница 108: ...6 36 6 OPTION 6 7 With wall mounting Attachment ...
Страница 124: ...8 10 8 COMMUNICATION CABLE 8 2 External Cable Relay Cable ...
Страница 172: ...11 16 11 COMMUNICATION INTERFACE SETTING COMMUNICATION SETTING 11 3 Ethernet Setting ...
Страница 200: ...12 28 12 DISPLAY AND OPERATION SETTINGS GOT SET UP 12 6 License Management ...
Страница 204: ...13 4 13 CLOCK SETTINGS AND BATTERY STATUS DISPLAY TIME SETTING AND DISPLAY 13 1 Time Setting and Display ...
Страница 296: ...14 92 14 FILE DISPLAY AND COPY PROGRAM DATA CONTROL 14 2 Various Data Control ...
Страница 320: ...15 24 15 GOT SELF CHECK DEBUG AND SELF CHECK 15 4 GOT start time ...
Страница 322: ...16 2 16 CLEANING DISPLAY SECTION CLEAN ...
Страница 336: ...17 14 17 INSTALLATION OF COREOS BOOTOS AND STANDARD MONITOR OS 17 5 CoreOS ...
Страница 360: ...19 8 19 MAINTENANCE AND INSPECTION 19 5 Backlight Shutoff Detection ...
Страница 382: ......
Страница 450: ...22 34 22 COMPUTER LINK CONNECTION 22 6 Precautions ...
Страница 508: ...23 58 23 ETHERNET CONNECTION 23 5 Precautions ...
Страница 526: ......
Страница 592: ...26 22 26 SERVO AMPLIFIER CONNECTION 26 7 Precautions ...
Страница 598: ...27 6 27 ROBOT CONTROLLER CONNECTION 27 6 Precautions ...
Страница 607: ...MULTIPLE GOT CONNECTION FUNCTION 29 MULTIPLE GOT CONNECTION FUNCTION 29 1 ...
Страница 608: ......
Страница 619: ...MULTI CHANNEL FUNCTION 30 MULTI CHANNEL FUNCTION 30 1 ...
Страница 620: ......
Страница 635: ...FA TRANSPARENT FUNCTION 31 FA TRANSPARENT FUNCTION 31 1 ...
Страница 636: ......
Страница 688: ...31 52 31 FA TRANSPARENT FUNCTION 31 7 Precautions ...
Страница 698: ...App 10 APPENDICES Appendix 2 Usage Condition of Utility Function ...
Страница 703: ......
Страница 704: ......
Страница 705: ......
Страница 706: ......
Страница 738: ...A 32 ...
Страница 748: ......
Страница 820: ...33 44 33 CONNECTION TO OMRON PLC 33 4 Device Range that Can Be Set ...
Страница 834: ...34 14 34 CONNECTION TO OMRON TEMPERATURE CONTROLLER 34 7 Precautions ...
Страница 912: ...37 22 37 CONNECTION TO JTEKT PLC 37 7 Precautions ...
Страница 930: ...38 18 38 CONNECTION TO SHARP PLC 38 6 Device Range that Can Be Set ...
Страница 980: ...41 16 41 CONNECTION TO TOSHIBA PLC 41 4 Device Range that Can Be Set ...
Страница 996: ...43 8 43 CONNECTION TO PANASONIC SERVO AMPLIFIER 43 7 Precautions ...
Страница 1028: ...44 32 44 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 44 6 Device Range that Can Be Set ...
Страница 1052: ...46 10 46 CONNECTION TO HITACHI PLC 46 6 Device Range that Can Be Set ...
Страница 1092: ...47 40 47 CONNECTION TO FUJI PLC 47 5 Precautions ...
Страница 1108: ...48 16 48 CONNECTION TO FUJI TEMPERATURE CONTROLLER 48 7 Precautions ...
Страница 1142: ...49 34 49 CONNECTION TO YASKAWA PLC 49 4 Device Range that Can Be Set ...
Страница 1332: ...55 28 55 CONNECTION TO GE PLC 55 7 Precautions ...
Страница 1348: ...56 16 56 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 56 6 Device Range that Can Be Set ...
Страница 1352: ...57 4 57 CONNECTION TO SICK SAFETY CONTROLLER 57 5 Device Range that Can Be Set ...
Страница 1368: ...58 16 58 CONNECTION TO SIEMENS PLC 58 4 Device Range that Can Be Set ...
Страница 1370: ...59 2 59 CONNECTION TO HIRATA CORPORATION HNC CONTROLLER ...
Страница 1372: ...60 2 60 CONNECTION TO MURATEC CONTROLLER ...
Страница 1373: ...MICROCOMPUTER CONNECTION 61 MICROCOMPUTER CONNECTION SERIAL 61 1 62 MICROCOMPUTER CONNECTION ETHERNET 62 1 ...
Страница 1374: ......
Страница 1515: ...MODBUS CONNECTIONS 63 MODBUS R RTU CONNECTION 63 1 64 MODBUS R TCP CONNECTION 64 1 ...
Страница 1516: ......
Страница 1537: ...CONNECTIONS TO PERIPHERAL EQUIPMENT 65 VNC R SERVER CONNECTION 65 1 ...
Страница 1538: ......
Страница 1545: ......
Страница 1546: ......