15 - 20
15.4 GOT Side Settings
■2.
Communication detail settings
Make the settings according to the usage environment.
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be changed on the Utility's [Communication
Settings] after writing [Controller Setting] of project data.
For details on the Utility, refer to the following manual.
➠
GOT2000 Series User's Manual (Utility)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the Utility, the latest setting is effective.
POINT
POINT
POINT
Cutting the portion of multiple connection of the controller
By setting GOT internal device, GOT can cut the portion of multiple connection of the controller.
For example, faulty station that has communication timeout can be cut from the system.
For details of the setting contents of GOT internal device, refer to the following manual.
➠
GT Designer3 (GOT2000) Screen Design Manual
Item
Description
Range
Transmission Speed
Set this item when change the transmission speed used for communication with the
connected equipment.
(Default: 9600bps)
9600bps, 19200bps,
38400bps, 57600bps
115200bps
Data Bit
Set this item when change the data length used for communication with the connected
equipment.
(Default: 8bit)
8bit (fixed)
Stop Bit
Specify the stop bit length for communications.
(Default: 1bit)
1bit (fixed)
Parity
Specify whether or not to perform a parity check, and how it is performed during
communication.
(Default: Even)
Even (fixed)
Retry
Set the number of retries to be performed when a communication timeout occurs.
(Default: 3times)
0 to 5times
Timeout Time
Set the time period for a communication to time out.
(Default: 3sec)
1 to 30sec
Host Address
Specify the station number of the servo amplifier in the system configuration.
(Default: 0)
0 to 31
Delay Time
Set this item to adjust the transmission timing of the communication request from the
GOT.
(Default: 0ms)
0 to 300 (ms)
Station No. Selection
Specify whether to use the station No. during communication.
If [Yes] is selected, the station No. is fixed to "0."
(Default: Yes)
Yes/No
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......