
12.2 System Configuration
12 - 9
CC-Link
C
O
NN
ECTION (INTELLIGE
NT DEVICE ST
A
T
ION)
12
12.2 System Configuration
12.2.1
Connecting with CC-Link Ver.1 compatible
*1
For the system configuration of the CC-Link module, refer to the following manuals.
➠
CC-Link System Master/Local Module User's Manual QJ61BT11N
Control & Communication Link System Master/Local Module Type AJ61QBT11/A1SJ61QBT11 User's Manual
Control & Communication Link System Master/Local Module Type AJ61BT11/A1SJ61BT11 User's Manual
MELSEC-L CC-Link System Master/Local Module User's Manual
*2
For the specifications and inquiries of the CC-Link dedicated cable, refer to the following.
➠
CC-Link Partner Association's home page: http://www.cc-link.org/
*3
The maximum overall extension cable length and the length between stations vary depending on the cable type to be used and
the transmission speed.
For details, refer to the following manual.
➠
CC-Link System Master/Local Module User's Manual QJ61BT11N
Control & Communication Link System Master/Local Module Type AJ61QBT11/A1SJ61QBT11 User's Manual
Control & Communication Link System Master/Local Module Type AJ61BT11/A1SJ61BT11 User's Manual
MELSEC-L CC-Link System Master/Local Module User's Manual
FX3U-16CCL-M USER'S MANUAL
*4
Transient transmission can be performed to only CC-Link modules of function version B or later and software version J or later.
*5
Specify Ver.1 as the mode setting in the Communication Settings to use it.
For details of the settings, refer to the following the manual.
➠
12.3.1 Setting communication interface (Controller Setting)
*6
When using an FX3U-16CCL-M with the MELSEC iQ-F series, bus conversion module (FX5-CNV-BUS or FX5-CNV-BUSC) is
required.
*7
MELSEC-FX do not support FX5-CCL-MS.
*8
GT25-W, GT2505-V does not support the option device.
PLC
Connection cable
GOT
Number of
connectable
equipment
Model name
CC-Link module
*1
Communication
type
Cable model
Max.
distance
Option device
*8
Model
MELSEC iQ-R Series
Motion controller CPU (MELSEC
iQ-R Series)
C Controller module (MELSEC
iQ-R Series)
CNC C80
CR800-R(R16RTCPU)
RJ61BT11
CC-Link (Ver.1)
CC-Link
dedicated cable
*2
*3
GT15-J61BT13
*5
26 GOTs
MELSEC-Q
(Q mode)
C Controller module
(Q Series)
Motion controller CPU (Q Series)
CNC C70
Robot controller (CRnQ-700)
QJ61BT11
QJ61BT11N
MELSEC-L
LJ61BT11
MELSEC-L
(L26CPU-BT)
-
MELSEC-QnA
AJ61QBT11
A1SJ61QBT11
*4
MELSEC-A
AJ61BT11
A1SJ61BT11
*4
MELSEC iQ-F series
*6
MELSEC-FX
*7
FX3U-16CCL-M
FX5-CCL-MS
8 GOTs
CC-Link
module
PLC
GOT
Connection cable
CC-Link Ver2(ID)
Communication driver
Содержание GOT2000 Series
Страница 2: ......
Страница 84: ......
Страница 432: ...6 58 6 6 Precautions ...
Страница 578: ...9 54 9 6 Precautions ...
Страница 726: ...12 84 12 5 Precautions ...
Страница 756: ......
Страница 822: ...14 66 14 4 Device Range that Can Be Set ...
Страница 918: ...15 96 15 7 Precautions ...
Страница 930: ...16 12 16 6 Precautions ...
Страница 963: ...MULTIPLE GOT CONNECTIONS 19 GOT MULTI DROP CONNECTION 19 1 20 MULTIPLE GT21 CONNECTION FUNCTION 20 1 ...
Страница 964: ......
Страница 1002: ...19 38 19 7 Precautions ...
Страница 1022: ...20 20 20 5 Precautions ...
Страница 1023: ...MULTI CHANNEL FUNCTION 21 MULTI CHANNEL FUNCTION 21 1 ...
Страница 1024: ......
Страница 1047: ...21 3 GOT Side Settings 21 23 21 MULTI CHANNEL FUNCTION Example Setting example for Ethernet connection 4 channels ...
Страница 1054: ...21 30 21 5 Multi channel Function Check Sheet ...
Страница 1055: ...FA TRANSPARENT FUNCTION 22 FA TRANSPARENT FUNCTION 22 1 ...
Страница 1056: ......
Страница 1223: ......