12 - 14
12. CONNECTION TO TOSHIBA PLC
12.4 Device Range that Can Be Set
TOSHIBA PLC
(TOSHIBA PROSEC T/V Series)
PROSEC T Series
*1
The writing of the timer (contact)/(current value) and counter
(contact)/(current value) are executed after being read by the
GOT. Therefore, do not edit it in the sequence program
during this period.
*2
As bit specification of a word device is performed after the
GOT reads the value, do not change the value in the
sequence program during this period.
*3
When the mode switch on the CPU module is set to "P-
RUN", writing to D0000 through D4095 is disabled.
*4
Extension file register is not supported.
PROSEC V Series
*2
As bit specification of a word device is performed after the
GOT reads the value, do not change the value in the
sequence program during this period.
*5
RW0000 and D0000 indicate the data register in the same
region although they are shown in different notations.
*6
For bit data, the conversion from the address notation for the
TOSHIBA PLC to that for the GOT is shown as follows.
Address notation for TOSHIBA PLC ÷ 16=Word address
(Quotient)...Bit address (Remainder)
*7
For word data, the conversion from the address notation for
the TOSHIBA PLC to that for the GOT is shown as follows.
TOSHIBA PLC
(Unified Controller nv Series)
Device name
Setting range
Device
No.
represen
tation
Bi
t de
vi
ce
External input (X)
X0000 to X511F
Hexadec
imal
External output (Y)
Y0000 to Y511F
Internal relay (R)
*6
R0000 to R4095F
Special relay (S)
*6
S0000 to S511F
Link register relay (Z)
Z0000 to Z999F
Link relay (L)
L0000 to L255F
Timer (Contact) (T)
*1
T0 to T999
Decimal
Counter (Contact) (C)
*1
C0 to C511
Word device bit
*2*6
Specified bit of the following
word devices
Data register
Link register
File register
-
W
o
rd device
External input (XW)
XW0 to XW511
Decimal
External output (YW)
YW0 to YW511
Internal relay (RW)*
*5*7
RW0 to RW4095
Special relay (SW)
*7
SW0 to SW511
Link relay (LW)
LW0 to LW255
Timer (Current value)
(T)
*1
T0 to T999
Counter (Current value)
(C)
*1
C0 to C511
Data register (D)
*3*5*7
D0 to D8191
Link register (W)
W0 to W2047
File register (F)
*4
F0 to F32767
Address
notation
for TOSHIBA
PLC
Address notation
for GOT
Conversion
S8191
S511F
(Decimal)
(Hexadecimal)
8191÷16= 511...15
R65535
R4095F
(Decimal)
(Hexadecimal)
65535÷16= 4095...15
Communication
format
Address notation
for TOSHIBA PLC
Address
notation
for GOT
16bit data
DW10
D10
32bit data
(Integer)
DD10
(Calculate the device
No. in 32-bit unit)
D20
(Real
number)
DF10
(Calculate the device
No. in 32-bit unit)
D20
Device name
Setting range
Device
No.
represent
ation
B
it device
External input (X)
X000000 to X16383F
Decimal
+Hexade
cimal
External input (X)
Y000000 to Y16383F
Internal relay (R)
R00000 to R8191F
Input variable (I)
I000000 to I16383F
Output variable (Q)
Q000000 to Q16383F
Special relay (S)
S00000 to S1023F
Wo
rd
d
e
vi
ce
External input (XW)
XW0 to XW16383
Decimal
External output (YW)
YW0 to YW16383
Internal relay (RW)
RW0 to RW8191
Special relay (SW)
SW0 to SW1023
Data register (D)
D0 to D8191
Decimal
File register (F)
F0 to F32767
Input variable (IW)
IW0 to IW16383
Output variable (QW)
QW0 to QW16383
User global (UG)
UG0 to UG262143
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......