9. CONNECTION TO SHARP PLC
9.5 PLC Side Setting
9 - 13
9
CONN
E
C
TION
T
O
S
H
ARP PLC
10
C
O
NN
ECTI
ON
T
O
SHI
N
KO
TECHN
OS IN
DIC
ATI
NG
C
O
NT
ROLLE
R
11
CONNECTION T
O
CH
INO
CONTROLLE
R
12
CONNECTION T
O
T
O
SHI
B
A
PL
C
13
CONNECTION T
O
T
O
SH
IB
A M
A
C
H
IN
E
PLC
14
CONNECTION T
O
P
A
NA
SONIC S
E
R
V
O
A
M
PL
IF
IE
R
15
CONNE
CTION T
O
PA
NA
SONIC
INDUSTRI
AL
DE
VI
CES
SU
NX
PLC
(4) Operation mode setting switch(SW3)
(5) Transmission speed setting switch (SW4)
Set the same transmission speed of the GOT.
For the transmission speed setting on the GOT side,
refer to the following.
9.4.1 Setting communication interface
(Communication settings)
(6) Function setting switch(SW0)
9.5.4
Connecting to the link unit
(JW-10CM or ZW-10CM)
Switch setting of link unit (JW-10CM and ZW-
10CM)
(1) Function setting switch(SW0)
(2) Station number switch(SW1,SW2)
(3) Operation mode setting switch(SW3)
Switch No.
Settings
Setting details
SW3-1
OFF (fixed)
Invalid
SW3-2
ON (fixed)
4-wire type
SW3-3
OFF (fixed)
Invalid
SW3-4
ON (fixed)
Even
Setting
*1
Setting details
0
19200bps
1
9600bps
2
4800bps
*1
Indicates only the transmission speeds that
can be set on the GOT side.
Settings
Setting details
4 (fixed)
Computer link
SW3
12
3
4
ON
OFF
SW4
C
B
A
9
8
7
6
5
F
E
D
4
3
2
1
0
SW0
C
B
A
9
8
7
6
5
F
E
D
4
3
2
1
0
Settings
Setting details
4 (fixed)
Computer link
(command mode)
Switch No.
Settings
Setting details
SW1
Station No.
lower digit
(10
0
digit)
1 (fixed)
SW2
Station No.
upper digit
(10
1
digit)
0 (fixed)
Switch No.
Settings
Setting details
SW3-1
OFF (fixed)
Invalid
SW3-2
ON (fixed)
4-wire type
SW3-3
OFF (fixed)
Invalid
SW3-4
ON (fixed)
Even
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
4
SW1
SW2
SW0
SW4
SW3
SW7
3
2
1
ON
OFF
(1)
(2)
(4)
(3)
(5)
ON
Inside the cover of switch setting
3
2
0
5
9
4
8
7
6
1
SW0
3
2
0
5
9
4
8
7
6
1
3
2
0
5
9
4
8
7
6
1
SW1
SW2
4
SW3
3
2
1
ON
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......