6.3 Ethernet Connection
6.3.1
Connecting to KV-700/1000/3000/5000/5500
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
GT16 User's Manual
*4
Product manufactured by KEYENCE CORPORATION. For details of the product, contact KEYENCE CORPORATION.
*5
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
Ethernet
module
CPU
GOT
Connection cable
Ethernet (KEYENCE), Gateway
Communication driver
PLC
Connection cable
GOT
Number of connectable
equipment
Series
Ethernet
module
*4
Cable model
Maximum
segment length
*2
Option device
Model
*3
KV-5000
-
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP):
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable (STP):
Category 5 and 5e
100m
- (Built into GOT)
When PLC:GOT is N:1
The following shows the
number of PLCs for 1 GOT
<For GT16, GT14>
TCP: 128 or less
UDP: 128 or less
<For GT15, GT12>
TCP: 10 or less
UDP: 128 or less
When PLC:GOT is 1:N
The following shows the
number of GOTs for 1 PLC
TCP: 15 or less
UDP: 1 or less
GT15-J71E71-100
KV-700
KV-1000
KV-3000
KV-5000
KV-5500
KV-LE20V
KV-LE21V
100m
- (Built into GOT)
GT15-J71E71-100
*5
*5
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......