3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.6 Device Range that Can Be Set
3.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may
not be monitored.
Setting item
*1
The following shows the relation between station numbers of the control equipment and the GOT data register.
For Azbil SDC/DMC Series
For Azbil DMC50
Item
Description
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Device definition can be checked.
Information
Displays the device type and setting range which are selected in [Device].
Network
Set the monitor target of the set device.
Station
To monitor the control equipment of the specified station No.
• When Azbil SDC/DMC Series is used.
0 to 127 :To monitor the control equipment of the specified station No.
200 to 215 :To specify the station No. of the control equipment to be monitored by the value of
GOT data register (GD).
*1
• When Azbil DMC50 is used.
1 to 15: To specify the station No. of the COM module or control equipment to be monitored.
100 to 115: To specify the station No. of the COM module or control equipment to be monitored,
and the Sub Station of the control equipment by the value of GOT data register (GD).
*2
Sub Station
Specify the sub station number of the control equipment connected to the COM module specified in
[Station] to monitor it. (0 to 15)If the specified [SubStation] is 0, the COM module/control equipment
specified in [Station] is monitored.
For AHC2001, the sub station number is ignored.
Station No.
GOT data register (GD)
Setting range
200
GD10
0 to 127
(If setting a value outside
the range above, a device
range error occurs.)
201
GD11
:
:
214
GD24
215
GD25
Содержание GOT 1000 Series
Страница 2: ......
Страница 76: ...1 46 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Страница 78: ......
Страница 114: ...2 36 2 CONNECTION TO IAI ROBOT CONTROLLER 2 7 Precautions ...
Страница 232: ...5 18 5 CONNECTION TO OMRON TEMPERATURE CONTROLLER 5 7 Precautions ...
Страница 254: ...6 22 6 CONNECTION TO KEYENCE PLC 6 4 Device Range that Can Be Set ...
Страница 404: ...14 14 14 CONNECTION TO PANASONIC SERVO AMPLIFIER 14 7 Precautions ...
Страница 426: ...15 22 15 CONNECTION TO PANASONIC INDUSTRIAL DEVICES SUNX PLC 15 6 Device Range that Can Be Set ...
Страница 432: ...REVISIONS 3 ...
Страница 435: ......