144
APPX
Appendix 3 Buffer Memory
Diagnostic information area
■
Diagnostic information area (Un\G23072 to Un\G23199)
This area stores diagnostic information on DP-Slaves generated during data exchange. (
diagnostic information and extended diagnostic information)
Diagnostic information area stores information on 64 stations in the same sorting order of data.
• 'Diagnostic information area' (Un\G23072 to Un\G23199) is assigned in the order of parameters configured
with PROFIBUS Configuration Tool (order of FDL address).
• Modifying the parameters with PROFIBUS Configuration Tool (adding or deleting a DP-Slave) causes the
buffer memory areas to be reassigned. Review the program after modifying the parameters.
• The information in 'Diagnostic information area' (Un\G23072 to Un\G23199) is not cleared by resolving the
problem that occurred to the relevant DP-Slaves. To clear the information in 'Diagnostic information area'
(Un\G23072 to Un\G23199), turn on 'Diagnostic information area clear request signal' (Un\G2.b2).
Address
Bit
Name
Description
Initial
value
Un\G23072
b8 to b15
Diagnostic information area
(1st station)
Stores the status 3 information on the 1st station (whether any piece of
diagnostic information other than the one sent this time is stored in the DP-
Slave).
• 00H: No other diagnostic information is stored.
• 80H: Other diagnostic information is stored.
00H
b0 to b7
Stores the FDL address for the 1st station.
• 00H to 7DH (0 to 125): FDL address
00H
Un\G23073
b8 to b15
Stores the status 1 information on the 1st station.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
b0 to b7
Stores the status 2 information on the 1st station.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
Un\G23074
b8 to b15
Diagnostic information area
(2nd station)
Stores the status 3 information on the 2nd station (whether any piece of
diagnostic information other than the one sent this time is stored in the DP-
Slave).
• 00H: No other diagnostic information is stored.
• 80H: Other diagnostic information is stored.
00H
b0 to b7
Stores the FDL address for the 2nd station.
• 00H to 7DH (0 to 125): FDL address
00H
Un\G23075
b8 to b15
Stores the status 2 information on the 1st station.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
b0 to b7
Stores the status 2 information on the 2nd station.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
Un\G23198
b8 to b15
Diagnostic information area
(64th station)
Stores the status 3 information on the 64th station (whether any piece of
diagnostic information other than the one sent this time is stored in the DP-
Slave).
• 00H: No other diagnostic information is stored.
• 80H: Other diagnostic information is stored.
00H
b0 to b7
Stores the FDL address for the 64th station.
• 00H to 7DH (0 to 125): FDL address
00H
Un\G23199
b8 to b15
Stores the status 64 information on the 1st station.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
b0 to b7
Stores the status 64 information on the 2nd station.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
Содержание FX5-DP-M
Страница 1: ...MELSEC iQ F FX5 User s Manual PROFIBUS ...
Страница 2: ......
Страница 9: ...7 MEMO ...
Страница 12: ...10 INDEX 168 REVISIONS 170 WARRANTY 171 TRADEMARKS 172 ...
Страница 13: ...11 CONTENTS ...
Страница 19: ...1 DESCRIPTION 17 1 MEMO ...
Страница 100: ...98 9 PROGRAMMING 9 2 DP Master settings DP Slave FDL address 2 ...
Страница 101: ...9 PROGRAMMING 9 2 DP Master settings 99 9 DP Slave FDL address 3 ...
Страница 108: ...106 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Страница 109: ...9 PROGRAMMING 9 8 Program Example of the Global Control Function 107 9 ...
Страница 110: ...108 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Страница 112: ...110 9 PROGRAMMING 9 9 Program Example of Acyclic Communication Acyclic Communication ...
Страница 114: ...112 9 PROGRAMMING 9 10 Program Example of the Alarm Acquisition Function ...
Страница 169: ...APPX Appendix 4 Processing Time 167 A MEMO ...
Страница 175: ......