background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D14801L

Side

B

Safety Precautions

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories:

 and 

.

Depending on the circumstances, procedures indicated by 

 may

also cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

How to obtain manuals

For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

User's Manual 
- Analog Control Edition

JY997D16701

MODEL CODE: 

09R619

Describes specifications for 

analog control and 

programming method for 

FX

3S

/FX

3G

/FX

3GC

/ FX

3U

/

FX

3UC

 Series PLC.

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

Programming Manual 
- Basic & Applied Instruction
Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming

for basic/applied instructions

and devices.

FX

3S

 Series 

User’s Manual 
- Hardware Edition

JY997D48601

MODEL CODE: 

09R535

Explain s FX

3S

 Serie s PLC

specifications for I/O, wiring,

installation, and maintenance.

FX

3G

 Series 

User’s Manual 
- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains FX

3G

 Series PLC

specifications for I/O, wiring,

installation, and maintenance.

FX

3GC

 Series 

User’s Manual 
- Hardware Edition

JY997D45401

MODEL CODE: 

09R533

Explains FX

3GC

 Series PLC

specifications for I/O, wiring,

installation, and maintenance.

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains FX

3U

 Series  PLC

specifications for I/O, wiring,

installation, and maintenance.

FX

3UC

 Series 

User’s Manual 
- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains FX

3UC

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

Applicable standards

FX

3U

-4AD-TC-ADP 

units made in June, 2005 or later comply with the EC Directive

(EMC Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.

→ 

FX

3S

 Series Hardware Manual (Manual No. JY997D48301)

→ 

FX

3G

 Series Hardware Manual (Manual No. JY997D46001)

→ 

FX

3GC

 Series Hardware Manual (Manual No. JY997D45201)

→ 

FX

3U

 Series Hardware Manual (Manual No. JY997D50301)

→ 

FX

3UC

 (D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)

→ 

FX

3UC

-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)

Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Attention

This product is designed for use in industrial applications.

Caution for EC Directive

The analog special adapters have been found to be compliant to the European 
standards in the aforesaid manual and directive. However, for the very best per-
formance from what are in fact delicate measuring and controlled output device 
Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered care-
fully. For users of proprietary cables (integral with sensors or actuators), these 
users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other 
EMC protection is provided, then users may experience temporary loss or 
accuracy between ±10 % in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are fol-
lowed for the users complete control system, users should expect accuracy as 
specified in this manual.

Sensitive analog cable should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible users should run analog
cables separately.

Good cable shielding should be used. When terminating the shield at Earth 

- ensure that no earth loops are accidentally created.

When reading analog values, EMC accuracy can be improved out by
averaging the readings. This can be achieved either through functions on the
analog special adapters or through a users program.

1. Outline

FX

3U

-4AD-TC-ADP (hereinafter called TC-ADP) is an analog special adapter for

measuring temperature via four channels of connected Type K or Type J thermocouple
thermometer.

1.1 Incorporated Items

Verify that the following product and items are included in the package:

1.2 External Dimensions, Part Names, and Terminal Layout 

Product

FX

3U

-4AD-TC-ADP K/J type thermocouple thermometer input

special adapter

Accessories

User’s manual (This manual)

[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock: 

Used to connect additional special adapters onto the left side of this special
adapter.

[4] Special adapters connector cover:

Remove this cover to connect additional special adapters to the left side.

[6]

[5]

[10]

[7]

[8]

[9]

[3]

[2]

[4]

Weight: Approx. 0.1 kg (0.22 lbs)

Special adapter 

connector cover 

is removed  

[11]

[1]

90(3.55")

98(3.86")

(mounting hole pitch)

106(4.18")

7(0.28")

74(2.92")

15.5

(0.62")

17.6

(0.7")

15.1

(0.6")

J-type

L2+

L2-

24+

24-

J-type

L1+

L3-

L4+

L4-

L3+

L1-

2. Installation

For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.

  

2.1 Connection to the PLC

This section describes the connection method to the PLC (FX

3U

 Series PLC is used for

the following example).
For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.

Procedure

1) Turn off the power.

Disconnect all the cables connected to the PLC main unit and special adapter, and
demount the main unit and special adapter mounted on DIN rail or mounted directly
using screws.

2) Install an expansion board to the main unit.

For the expansion board installation procedure, refer to the following manual:

→ 

FX

3U

 Series User's Manual - Hardware Edition

3) Remove the special adapter connector cover on

the expansion board (fig.A).
When connecting this product to another special
adapter, please replace the 'expansion board' in
the above description with a 'special adapter' and
perform the procedure as indicated.

4) Slide the special adapter slide lock 

(fig.B) of the main unit.
When connecting this product to another special
adapter, please replace the 'main unit' in the
above description with a 'special adapter' and
perform the procedure as indicated. (Please
replace the following procedures similarly.)

[5] Direct mounting hole:2 holes of 

φ

4.5 (0.18") (mounting screw: M4 screw)

Not used when connecting to FX

3GC

/FX

3UC

 Series PLC.

[6] POWER LED (green):

Lit while 24 V DC power is supplied properly to terminals '24+' and '24-'.

[7] Terminal block (European type):

Connect thermocouple sensor input, Type K or J changeover input, and 24 V DC
power supply.

[8] Special adapter connector:

Used to connect this special adapter to PLC main unit or special adapter.

[9] DIN rail mounting hook
[10] Special adapter fixing hook
[11] Special adapter connector:

Used to connect communication or analog special adapters to the left side of the
TC-ADP.

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl

2

, H

2

S, SO

2

 or NO

2

), flammable gas, vibration or impacts,

or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Do not touch the conductive parts of the product directly. 
Doing so may cause device failures or malfunctions.

Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.

RUN

STOP

FX

3U

-48MR/ES

-48MR/ES

FX

3U-48M

3)

4)

B

B

A

4)

5) Connect the 

special adapter 
(fig.C) to the 
main unit as 
shown on the 
right

.

6) Slide back the 

special adapter
slide lock (fig.B)
of the main unit
to fix the special
adapter (fig.C). 

Connection precautions

Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.

Do not connect a high-speed I/O special adapter on the left side of any
special adapters other than other high-speed I/O special adapters.

3. Wiring  

3.1 Applicable cable and terminal tightening torque

3.1.1

Type terminal block (European type)

1) Wire size

- The power supply wiring and the Type K/J changeover input wiring should 

use 22-20 AWG wire.

- Thermocouple wiring should use the compensating lead wire suitable for 

the type of thermocouple.

→ 

For details of compensating lead wire, Refer to Section 3.3

2) Applicable cable

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

WIRING 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to observe the following precautions in order to prevent
malfunctions under the influence of noise:

1) Do not bundle the power line or shield of the analog input/output cable

together with or lay it close to the main circuit, high-voltage line, or load
line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100 mm (3.94") or more
away from the main circuit, high-voltage line, or load line.

2) Ground the shield of the analog input/output cable at one point on the

signal receiving side. However, do not use common grounding with heavy
electrical systems.

Make sure to properly wire to the terminal block (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.

- The disposal size of the cable end should follow the dimensions 

described in the manual.

- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires 

of unspecified size.

- Affix the electric wires so that neither the terminal block nor the connected 

parts are directly stressed.

Type

Wire size

Single-wire

0.3 mm

2

 to 0.5 mm

2

 (AWG22 to 20)

2-wire

2 pieces of 0.3 mm

2

 (AWG22)

RUN

STOP

FX

FX

3U

3U

-48MR/ES

-48

MR

/ES

FX

FX

3U

3U

-48M

-48M

PO

WE

R

FX

3U-*** -

***

FX

3U-48M

6)

C

B

B

5)

5)

5)

6)

3) Termination of cable end

Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve.
<Reference> 

*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6

When using a ferrule with insulation sleeve, choose a wire with proper cable

sheath referring to the above outside dimensions, or otherwise, the wire
cannot be inserted easily. The tightening torque must be 0.22 to 0.25 N

m. Do

not tighten terminal screws with a torque outside the above-mentioned range.
Failure to do so may cause equipment failures or malfunctions.

3.2 Power Supply Wiring

For the power supply wiring, refer to the following manual.

→ 

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 Series User’s Manual - Analog Control

Edition

3.3 Selection of thermocouple

→ 

For the terminal configuration, refer to Section 1.2

Precautions on thermocouple wiring

Thermocouple type

- There are 2 types of thermocouples: Type K and Type J. Select the desired 

type. However, be sure to connect the same type of thermocouple to all the 

channels.

- Use insulated thermocouple types.

Compensating lead 

wire To connect the 

thermocouple, use 

one of the right types

of compensating lead

wires. 

The compensating 

lead wire indicates the temperature value of approximately 0.12 

°

C higher than

that of the wire resistor (10 

). Temperature value should be used in

consideration of this point.

If the compensating lead wire is very long, the wire may be easily affected by

noise, etc. It is, therefore, recommended that the length of the compensating

lead wire should be 100 m (328' 1") or less.

Example of thermocouple wiring

*1 When using the Type J thermocouple, short-circuit the 'Type J' terminals

and turn the special auxiliary relay (Type K/J mode changeover) ON.

For details of auxiliary relays, refer to the following manual.

→ 

 FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 Series User's Manual - Analog Control

Edition

*2 24 V DC service power supply of the FX

3S

/FX

3G

/FX

3U

 Series PLC can also

be used.

Manufacturer

Model

Caulking tool

Phoenix Contact Co., Ltd.

AI 0.5-8WH

CRIMPFOX 6

*1

(or CRIMPFOX 6T-F

*2

)

9 mm

(0.35")

- Strand wire/single wire

8 mm

(0.31")

Contact area

(Crimp area)

14 mm (0.55")

2.6 mm (0.1")

Insulation sleeve

- Ferrule with insulation sleeve

Thermocouple Type of compensating lead wire

Type K

KX, KCA, KCB, KCC

Type J

JX

3 k

TC-ADP

L   +
L    -

24+

24-

Compensating lead

wire (Shielded)

Terminal

block

24 V DC

External power

supply wiring

J-type
J-type

Thermocouple

*1

Thermocouple Wiring

Using Type J

Temperature

compensation circuit

*2

ch

ch

Grounding

(Ground resistance: 100

 or less)

L   +, L   -, ch    :    represents the channel number.

L   +
L    -

Temperature

compensation circuit

3 k

+5 V

3.4 Grounding

Grounding should be performed as stated below.

The grounding resistance should be 100 

 or less.

Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding" of the
following figure.
For details, refer to the respective PLC User's manual Hardware Edition.

The grounding wire size should be AWG 22-20 (0.3-0.5 mm

2

).

The grounding point should be close to the PLC, and all grounding wire should be
as short as possible.

4. Specifications 

4.1 Applicable PLC

The version number can be checked by monitoring D8001/D8101 as the last three
digits indicate it.

4.2 General Specifications

Items other than the following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC User's manual Hardware
Edition.

4.3 Power Supply Specifications

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric representative.

Do not drop the product or exert strong impact to it.
Doing so may cause damage.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. 
Failure to do so may cause failures in the product. 
After transportation, verify operation of the product and check for damage of the
mounting part, etc.

Model name

Applicability

FX

3S

 Series PLC

Ver. 1.00 or later (from first production)

FX

3G

 Series PLC

Ver. 1.00 or later (from first production)

FX

3GC

 Series PLC Ver. 1.40 or later (from first production)

FX

3U

 Series PLC

Ver. 2.20 or later (from first production)

FX

3UC

 Series PLC

Ver. 1.30 or later (from the production manufactured in August,
2004 with SER No. 48****)

Item

Specification

Dielectric withstand 
voltage

500 V AC for one minute

Between all terminals and
ground terminal of PLC
main unit

Insulation resistance

5 M

 o r h igh er by 500 V DC

insulation resistance tester

Item

Specification

A/D conversion 
circuit driving power

24 V DC +20 %/-15 %, 45 mA for 24 V DC
Connect a 24 V DC power supply to the terminal block.

Interface driving 
power

5 V DC, 15 mA
5 V DC power is supplied from the internal power supply of
main unit.

PLC

Other

equipment

PLC

Other

equipment

PLC

Other

equipment

Shared grounding

(Good condition)

Common grounding

(Not allowed)

Independent grounding

(Best condition)

4.4 Performance Specifications

Item

Specifications

Centigrade (

°

C)

Fahrenheit (

°

F) 

Input signal

Thermocouple type K or J

JIS C 1602-1995

Rated 
temperature 
range

Type K

-100 

°

C to +1000 

°

C

Type K

-148 

°

F to +1832 

°

F

Type J

-100 

°

C to +600 

°

C

Type J

-148 

°

F to +1112 

°

F

Digital output

Type K

-1000 to +10000

Type K

-1480 to +18320

Type J

-1000 to +6000

Type J

-1480 to +11120

Resolution

Type K

0.4 

°

C

Type K

0.72 

°

F

Type J

0.3 

°

C

Type  J

0.54 

°

F

Total accuracy

±

(0.5 % full scale +1 

°

C)

A/D conversion 
time

FX

3U

/FX

3UC

 Series PLC: 200 

µ

(The data will be updated at every scan time of the PLC.)

FX

3S

/FX

3G

/FX

3GC

 Series PLC: 250 

µ

s

(The data will be updated at every scan time of the PLC.)

Input 
characteristics

Insulation 
method

The photocoupler is adopted to insulate the analog input area
from the PLC.

The DC/DC converter is adopted to insulate the power supply
line from the analog input area.

A channels are not insulated from each other.

Occupied 
points

0 point (This number is not related to the maximum number of
input/output points of the PLC.)

0

+600

°

C

+6000

-100

°

C

-1000

+610

°

C

Type J

+6100

-1100

-110

°

C

0

+1000

°

C

+10000

-100

°

C

-1000

-110

°

C

+

101

0

°

C

Type K

+10100

-1100

0

+1832

°

F

+18320

-148

°

F

-1480

-1

66

°

F

+1850

°

F

Type K

+18500

-1660

0

+1112

°

F

+11120

-148

°

F

-1480

+1130

°

F

Type J

+11300

-1660

-1

66

°

F

含有有害6物质的名称,含有量,含有部品

 

本产品中所含有的有害6 物质的名称,含有量,含有部品如下表所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定

 的限量要求以下。 

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 
    26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.

FX

3U

-4AD-TC-ADP

USER'S MANUAL

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration: 
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.

Effective June 2017
Specifications are subject to change without notice.

©

 2005 Mitsubishi Electric Corporation

Manual Number JY997D14801

Revision

L

Date

June 2017

Отзывы: