background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D35601F

Side

B

Safety Precautions

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories:

 and 

.

Depending on the circumstances, procedures indicated by 

 may

also cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

How to obtain manuals

For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

User's Manual 
- Analog Control Edition

JY997D16701

MODEL CODE: 

09R619

Describes specifications for 
analog control and 
programming method for 
FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series PLC.

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

Programming Manual 
- Basic & Applied Instruction
Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming for 
basic/applied instructions and 
devices.

FX

3S

 Series 

User’s Manual 
- Hardware Edition

JY997D48601

MODEL CODE: 

09R535

E xp la in s  FX

3 S

 Se rie s P L C

specifications for I/O, wiring,
installation, and maintenance.

FX

3G

 Series 

User’s Manual 
- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

E xpl ain s FX

3 G

  S erie s  PL C

specifications for I/O, wiring,
installation, and maintenance.

FX

3GC

 Series 

User’s Manual 
- Hardware Edition

JY997D45401

MODEL CODE:

09R533

Explains FX

3G C

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE:

09R516

E xp la ins   FX

3 U

 Se rie s PL C

specifications for I/O, wiring,
installation, and maintenance.

FX

3UC

 Series 

User’s Manual 
- Hardware Edition

JY997D28701

MODEL CODE:

09R519

Explains FX

3U C

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

Applicable standards

FX

3U

-3A-ADP 

units made in June, 2009 or later comply with the EC Directive (EMC

Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.

→ 

FX

3S

 Series Hardware Manual (Manual No. JY997D48301)

→ 

FX

3G

 Series Hardware Manual (Manual No. JY997D46001)

→ 

FX

3GC

 Series Hardware Manual (Manual No. JY997D45201)

→ 

FX

3U

 Series Hardware Manual (Manual No. JY997D50301)

→ 

FX

3UC

 (D, DS, DSS) Series Hardware Manual (Manual No. JY997D50501)

→ 

FX

3UC

-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)

Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Attention

This product is designed for use in industrial applications.

Caution for compliance with EC Directive

The analog special adapters have been found to be compliant to the European
standards in the aforesaid manual and directive. However, for the very best
performance from what are in fact delicate measuring and controlled output
device Mitsubishi Electric would like to make the following points;
As analog devices are sensitive by nature, their use should be considered
carefully. For users of proprietary cables (integral with sensors or actuators),
these users should follow those manufacturers installation requirements.
Mitsubishi Electric recommend that shielded cables should be used. If NO other
EMC protection is provided, then users may experience temporary loss or
accuracy between ±10 % in very heavy industrial areas.
However, Mitsubishi Electric suggest that if adequate EMC precautions are
followed for the users complete control system, users should expect accuracy
as specified in this manual.

Sensitive analog cable should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible users should run analog
cables separately.

Good cable shielding should be used. When terminating the shield at Earth 
- ensure that no earth loops are accidentally created.

When reading analog values, EMC accuracy can be improved out by
averaging the readings. This can be achieved either through functions on the
analog special adapters or through a users program.

1. Outline

The FX

3U

-3A-ADP special adapter for analog input and output (hereinafter called 

3A-ADP) is a special adapter that adds to add two analog input points and one analog
output point.

1.1 Incorporated Items

Verify that the following product and items are included in the package: 

1.2 External Dimensions, Part Names, and Terminal Layout 

Product

FX

3U

-3A-ADP analog input and output special adapter

Accessories

User’s Manual (This manual)

[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock: 

Used to connect additional special adapters onto the left side of this special
adapter.

[4] Special adapter connector cover:

Remove this cover to connect additional special adapters to the left side.

7(0.28") 74(2.92")

15.5

(0.62")

90(3.55")

98(3.86")

(mounting hole pitch)

106(4.18")

17.6

(0.7")

15.1

(0.6")

[6]

[5]

[10]

[7]

[8]

[9]

[3]

[2]

[4]

Weight: Approx. 0.1 kg (0.22 lbs)

Special adapter 

connector cover 

is removed  

[11]

[1]

V1+

I1+

COM2

VO

24+

24-

COM1

V2+

COM

IO

I2+

2. Installation

For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.

  

2.1 Connection to the PLC

This section describes the connection method to the PLC (FX

3U

 Series PLC is used for

the following example).
For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.

Procedure

1) Turn off the power.

Disconnect all the cables connected to the PLC main unit and special adapter, and
demount the main unit and special adapter mounted on DIN rail or mounted directly
using screws.

2) Install an expansion board to the main unit.

For the expansion board installation procedure, refer to the following manual:

→ 

FX

3U

 Series User's Manual - Hardware Edition

3) Remove the special adapter connector cover

on the expansion board (fig.A).
When connecting this product to another
special adapter, please replace the
'expansion board' in the above description
with a 'special adapter' and perform the
procedure as indicated.

4) Slide the special adapter slide lock (fig.B) of

the main unit.
When connecting this product to another
special adapter, please replace the 'main unit'
in the above description with a 'special
adapter' and perform the procedure as
indicated. (Please replace the following
procedures similarly.)

[5] Direct mounting hole:2 holes of 

φ

4.5 (0.18") (mounting screw: M4 screw)

Not used when connecting to FX

3GC

/FX

3UC

 Series PLC.

[6] POWER LED (green):

Lit while 24 V DC power is supplied properly to terminals '24+' and '24-'.

[7] Terminal block (European type):

Connect the analog voltage/current signal, and 24 V DC power supply.

[8] Special adapter connector:

Used to connect this special adapter to PLC main unit or special adapter.

[9] DIN rail mounting hook
[10] Special adapter fixing hook
[11] Special adapter connector:

Used to connect communication or analog special adapters to the left side of the
3AD-ADP.

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl

2

, H

2

S, SO

2

, or NO

2

), flammable gas, vibration or

impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Do not touch the conductive parts of the product directly. 
Doing so may cause device failures or malfunctions.

Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.

RUN

STOP

FX

FX

3U

3U

-48MR/ES

-48

MR

/ES

FX

3U-48M

3)

4)

B

B

A

4)

5) Connect the 

special adapter 
(fig.C) to the main 
unit as shown on 
the right.

6) Slide back the 

special adapter 
slide lock (fig.B) 
of the main unit to 
fix the special 
adapter (fig.C).

Connection precautions

Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.

Do not connect a high-speed I/O special adapter on the left side of any
special adapters other than other high-speed I/O special adapters.

3. Wiring

  

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

WIRING 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does
not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
PLC under the influence of noise:

1) Do not bundle the power line or shield of the analog input/output cable

together with or lay it close to the main circuit, high-voltage line, or load
line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit, high-voltage line, or load line.

2) Ground the shield of the analog input/output cable at one point on the

signal receiving side. However, do not use common grounding with heavy
electrical systems.

Make sure to properly wire to the terminal block (European type) in
accordance with the following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.

- The disposal size of the cable end should follow the dimensions 

described in the manual.

- Tightening torque should follow the specifications in the manual.
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires 

of unspecified size.

- Affix the electric wires so that neither the terminal block nor the connected 

parts are directly stressed.

Make sure to properly wire the terminal block in accordance with the
following precautions.
Failure to do so may cause electric shock, equipment failures, a short-circuit,
wire breakage, malfunctions, or damage to the product.

- The disposal size of the cable end should follow the dimensions 

described in the manual of the PLC main unit.

- Tightening torque should follow the specifications in the manual of the 

PLC main unit.

RUN

STOP

FX

3U

-48MR/ES

-48MR/E

S

FX

3U

-48M

-48M

0

IN

10

11

POWE

R

FX

3U-*** -

***

FX

3U-48M

6)

C

B

B

5)

5)

5)

6)

3.1 Applicable Cable and Terminal Tightening Torque

3.1.1

Terminal block (European type)

1) Wire size

Wiring to analog device should use 22-20 AWG wire.

2) Applicable cable

3) Termination of cable end

Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve.
<Reference>

*1 Old model name: CRIMPFOX ZA 3
*2 Old model name: CRIMPFOX UD 6

When using a stick terminal with insulating sleeve, choose a wire with proper
cable sheath referring to the above outside dimensions, or otherwise, the wire
cannot be inserted easily.
The tightening torque must be 0.22 to 0.25 N

m. Do not tighten terminal

screws with a torque outside the above-mentioned range. Failure to do so may
cause equipment failures or malfunctions.

3.2 Power Supply Wiring

For the power supply wiring, refer to the following manual.

→ 

FX

3S/

FX

3G/

FX

3GC/

FX

3U

/FX

3UC

 Series User’s Manual - Analog Control

Edition

3.3 Wiring of Analog Input

→ 

For the terminal configuration, refer to Section 1.2

*1 Use 2-core shielded twisted pair cable for the analog input lines, and

separate the analog input lines from other power lines or inductive lines.

*2 Make sure to short-circuit the 'V

…

+' and 'I

…

+' terminals when current is

input. 
(

…

: input channel number)

*3 24 V DC service power supply of the FX

3S

/FX

3G

/FX

3U

 Series PLC can also

be used.

Type

Wire size

Single-wire

0.3 mm

2

 to 0.5 mm

2

 (AWG22 to 20)

2-wire

2 pieces of 0.3 mm

2

 (AWG22)

Manufacturer

Model

Caulking tool

Phoenix Contact Co., Ltd.

AI 0.5-8WH

CRIMPFOX 6

*1

(or CRIMPFOX 6T-F

*2

)

9mm

(0.35")

- Strand wire/single wire

8mm

(0.31")

Contact area
(Crimp area)

14mm(0.55")

2.6mm(0.1")

Insulation sleeve

- Stick terminal with insulating sleeve

250

Ω

110k

Ω

ch

88.7k

Ω

3A-ADP

V   +, I   +, ch    :    represents the channel number.

Terminal

block

I   +

COM

V   +

*1

I   +

V   +

250

Ω

110k

Ω

ch

24+

24-

24 V DC

+15V

*1

*3

Using current

input

Using voltage input

*2

External power

supply wiring

Grounding

COM

88.7k

Ω

3.4 Wiring of Analog Output

→ 

For the terminal configuration, refer to Section 1.2

*1 Use 2-core shielded twisted pair cable for the analog output lines, and separate

the analog output lines from other power lines or inductive lines.

*2 Ground the shielded wire at one point on the signal receiving side.

3.5 Grounding

Grounding should be performed as stated below.

The grounding resistance should be 100 

Ω

 or less.

Independent grounding should be performed for best results.
When independent grounding is not performed, perform "shared grounding" of the
following figure.
For details, refer to the respective PLC User's manual Hardware Edition.

The grounding wire size should be AWG 22-20 (0.3-0.5 mm

2

).

The grounding point should be close to the PLC, and all grounding wire should be
as short as possible.

4. Specifications

4.1  Applicable PLC

The version number can be checked by monitoring D8001/D8101 as the last three
digits indicate it.

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
* For repair, contact your local Mitsubishi Electric representative.

Do not drop the product or exert strong impact to it.
Doing so may cause damage.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The product is a precision instrument. During transportation, avoid impacts larger
than those specified in the general specifications by using dedicated packaging
boxes and shock-absorbing palettes. 
Failure to do so may cause failures in the product. 
After transportation, verify operation of the product and check for damage of the
mounting part, etc.

Model name

Applicability

FX

3S

 Series PLC

Ver. 1.00 or later (from first production)

FX

3G

 Series PLC

Ver. 1.20 or later

FX

3GC

 Series PLC

Ver. 1.40 or later (from first production)

FX

3U

 Series PLC

Ver. 2.61 or later

FX

3UC

 Series PLC

Ver. 2.61 or later

Using voltage

output

3A-ADP

COM

Terminal

block

VO

IO

*1

*2 Grounding

Using current

output

3A-ADP

COM

Terminal

block

VO

IO

*1

*2 

Grounding

PLC

PLC

PLC

Other

equipment

Shared grounding

Good condition

Common grounding

Not allowed

Independent grounding

Best condition

Other

equipment

Other

equipment

4.2 General Specifications

Items other than the following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC User's manual Hardware
Edition.

4.3 Power Supply Specifications

4.4 Performance Specifications

Performance Specifications of Analog Input

Performance Specifications of Analog Output

Item

Specification

Dielectric withstand 
voltage

500 V AC for one minute

Between all terminals and
ground terminal of PLC
main unit

Insulation resistance

5 M

Ω

 or higher by 500 V DC 

insulation resistance tester

Item

Specification

Conversion circuit 
driving power

24 V DC +20 % / -15 %, 90 mA
Connect a 24 V DC power supply to the terminal block.

Interface driving 
power

5 V DC, 20 mA
5 V DC power is supplied from the internal power supply of
main unit.

Item

Specification

Voltage input

Current input

Analog input 
range

0 to 10 V DC

(Input resistance: 198.7 k

Ω

)

4 to 20 mA DC

(Input resistance: 250 

Ω

)

Maximum 
absolute input

-0.5 V, +15 V

-2 mA, +30 mA

Resolution

2.5 mV (10 V/4000)

μ

A (16 mA/3200)

Total accuracy

• ±

0.5 % (

±

50 mV) for full scale 

of 10 V (when ambient 
temperature is 25 

°

C

±

°

C)

• ±

1.0 % (

±

100 mV) for full 

scale of 10 V (when ambient 
temperature is 0 

°

C to 55 

°

C)

• ±

0.5 % (

±

80 

μ

A) for full scale 

of 16 mA (when ambient 
temperature is 25 

°

C

±

°

C)

• ±

1.0 % (

±

160 

μ

A) for full 

scale of 16 mA (when 
ambient temperature is 0 

°

to 55 

°

C)

Input 
characteristics

Item

Specification

Voltage output

Current output

Analog 
output 
range

0 to 10 V DC

(External load: 5 k

Ω

 to 1 M

Ω

)

4 to 20 mA DC

(External load: 500 

Ω

 or less)

Resolution

2.5 mV (10 V/4000)

μ

A (16 mA/4000)

Total 
accuracy

• ±

0.5 % (

±

50 mV) for full scale 

of 10 V (when ambient 
temperature is 25 

°

C

±

°

C)

• ±

1.0 % (

±

100 mV) for full scale 

of 10 V (when ambient 
temperature is 0 

°

C to 

55 

°

C)

If the external load resistance (Rs) 
is less than 5 k

Ω

, the accuracy will 

be increases as  shown in the 
following formula: (Addition will be 
100 mV per %.)

for full scale of 10 V

• ±

0.5 % (

±

80 

μ

A) for full scale 

of 16 mA (when ambient 
temperature is 
25 

°

C

±

5

 °

C)

• ±

1.0 % (

±

160 

μ

A) for full scale 

of 16 mA (when ambient 
temperature is 0 

°

C to 55 

°

C)

Output 
characteristics

Digit

al out

put

Analog input

0

10.2V

4080

4000

10V

Digit

al out

put

Analog input

0

20.4mA

3280

4mA

3200

20mA

Rs+47

47×100

0.9 %

Anal

og output

Digital input

0

4080

10V

4000

Anal

og output

Digital input

0

4080

4mA

20mA

4000

Common Specifications of Analog Input and Output

Item

Specification

Digital 
input and 
output

12 bits, binary

Conversion 
time

FX

3U

/FX

3UC

 Series PLC: 80 

μ

s for each selected input channel

+ 40 

μ

s for each selected output channel

(The data will be updated at every scan time of the PLC.)

FX

3S

/FX

3G

/FX

3GC

 Series PLC: 90 

μ

s for each selected input

c 50 

μ

s for each selected output channel

(The data will be updated at every scan time of the PLC.)

Insulation 
method

A photocoupler is employed to insulate the analog input and
output area from the PLC.

A DC/DC converter is employed to insulate the power supply
line from the analog input and output area.

Channels are not insulated from each other.

Occupied 
points

0 point (This number is not related to the maximum number of
input/output points of the PLC.)

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6 物质的名称,含有量,含有部品如下表

所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572

 规定的限量要求以下。 

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 
    26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

FX

3U

-3A-ADP

USER'S MANUAL

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.

Effective January 2017
Specifications are subject to change without notice.

©

 2009 Mitsubishi Electric Corporation

Manual Number JY997D35601

Revision

F

Date

January 2017

Отзывы: