(2) Verifying the parameters
The copied parameter settings stored in the FR-LU08(-01) and those in an inverter can be verified.
NOTE
• If an error occurs in verification on items other
than parameters, such as the setting frequency,
only [Verify Error] is displayed.
3.2.5
Option installation monitor
Displays the connection status of option connectors (of up to
6 letters). When no option is connected, [----] is displayed.
Turn
to display the installed terminal block option (of up
to 20 letters).
1
Copy the parameter settings of the source inverter to the FR-
LU08(-01). (Refer to
2
Connect the FR-LU08(-01) to the target inverter.
3
Display the Function menu,
turn
to move the cursor
to [Parameter copy], and
press .
4
Turn
to select the target
copy area, and press
.
5
Turn
to move the cursor
to [3: Verifying], and press
.
6
A confirmation screen appears for verification. Press
to
execute the verification.
P R E V
S E T
N E X T
Function menu
Terminal assignment
Parameter copy
S/W Version
SET
STOP
PU
▼
▲
(SET)
P R E V
S E T
N E X T
Parameter copy
CopyArea1
ABCDEFGHI
CopyArea2
CopyArea3
SET
STOP
PU
K
BACK
(SET)
BACK
S E T
N E X T
CopyArea1
ABCDEFGHI
1 : Read VFD
2 : Write VFD
3 : Verifying
SET
STOP
PU
(SET)
(SET)
7
If a verification error occurs,
the verification is stopped and
an error screen appears.
Press
to continue the
verification.
Press
to end the
verification.
S E T
3 : Verifying
ABCDEFGHI
Verify Error
1 Max. frequency
S E T
S E T
STOP
PU
NEXT
ABORT
(NEXT)
(ABORT)
S E T
N E X T
Option Instl Mntr
OP1 : ----
OP2 : A8AY
OP3 : ----
BACK
S E T
N E X T
STOP
PU
S E T
N E X T
Terminal Block :
A8TA
BACK
S E T
N E X T
▼
▲
Option Instl Mntr
STOP
PU