![Mitsubishi Electric FR-F800 Скачать руководство пользователя страница 765](http://html.mh-extra.com/html/mitsubishi-electric/fr-f800/fr-f800_instruction-manual_1811884765.webp)
Precautions for maintenance and inspection
Inspection item
FR-F800
7 - 5
7.1.5 Cleaning
Always run the inverter in a clean status.
When cleaning the inverter, gently wipe dirty areas with a soft cloth immersed in neutral detergent or
ethanol.
7.1.6 Replacement
of
parts
The inverter consists of many electronic parts such as semiconductor devices.
The following parts may deteriorate with age because of their structures or physical characteristics,
leading to reduced performance or fault of the inverter. For preventive maintenance, the parts must
be replaced periodically.
Use the life check function as a guidance of parts replacement.
Estimated lifespan for when the yearly average surrounding air temperature is 40 °C.
(Without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Output current: 80% of the inverter rating
NOTES
Do not use solvent, such as acetone, benzene, toluene and alcohol, as these will cause the inverter
surface paint to peel off.
The display, etc. of the operation panel and the parameter unit are vulnerable to detergent and
alcohol. Therefore, avoid using them for cleaning.
Part name
Estimated lifespan
Description
Cooling fan
10 years
Replace (as required)
Main circuit smoothing capacitor
10 years
Replace (as required)
On-board smoothing capacitor
10 years
Replace the board (as required)
Relays
⎯
As required
Main circuit fuse
(FR-F840-04320(185K) or higher)
10 years
Replace the fuse (as required)
Tab. 7-3:
Wearing parts
NOTES
For parts replacement, contact the nearest Mitsubishi FA center.
Содержание FR-F800
Страница 2: ......
Страница 4: ......
Страница 28: ...Related manuals Introduction 1 8 ...
Страница 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Страница 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Страница 720: ...Checking parameters changed from their initial values Initial value change list Parameters 5 558 ...
Страница 780: ...Measurement of main circuit voltages currents and powers Precautions for maintenance and inspection 7 20 ...
Страница 806: ...Outline dimension drawings Specifications 8 26 ...
Страница 833: ......