226
Communication operation and setting
4.20.5 Mitsubishi inverter protocol (computer link communication)
(1) Communication
The communication specifications are given below.
(2) Communication procedure
If a data error is detected and a retry must be made, execute retry operation with the user program. The inverter trips if the number of consecutive retries
exceeds the parameter setting.
On receipt of a data error occurrence, the inverter returns reply data 3) to the computer again. The inverter trips if the number of consecutive data errors
reaches or exceeds the parameter setting.
You can perform parameter setting, monitoring, etc. from the PU connector of the inverter using the Mitsubishi inverter
protocol (computer link communication).
Item
Description
Related
Parameter
Communication protocol
Mitsubishi protocol (computer link)
Pr. 549
Conforming standard
EIA-485 (RS-485)
—
Number of connectable devices
1:N (maximum 32 units), setting is 0 to 31 stations
Pr. 117
Communication
speed
PU connector
Selected among 4800/9600/19200/38400bps
Pr. 118
Control procedure
Asynchronous
—
Communication method
Half-duplex
—
Communication
Character system
ASCII (7 bits or 8 bits can be selected)
Pr. 119
Start bit
1 bit
—
Stop bit length
1 bit or 2 bits can be selected
Pr. 119
Parity check
Check (with even or odd parity) or no check can be selected
Pr. 120
Error check
Sum code check
—
Terminator
CR/LF (presence/absence selectable)
Pr. 124
Waiting time setting
Selectable between presence and absence
Pr. 123
Data communication between the computer and
inverter is made in the following procedure.
1) Request data is sent from the computer to
the inverter. (The inverter will not send data
unless requested.)
2) After waiting for the waiting time
3) The inverter sends reply data to the computer
in response to the computer request.
4) After waiting for the inverter data processing
time
5) Answer from the computer in response to
reply data 3) of the inverter is transmitted.
(Even if 5) is not sent, subsequent
communication is made properly.)
When data is read
When data is written
1)
5)
4)
3)
2)
*1
*2
Computer
(Data flow)
Inverter
Computer
(Data flow)
Inverter
Time