12. (M) Item and Output Signal for Monitoring
12.6 Output terminal function selection
NOTE
• The RUN signal (positive logic) is initially assigned to the terminal RUN (standard models only).
Forward rotation output (Y30) signal and Reverse rotation output (Y31)
signal
• Under Vector control, the Forward rotation output (Y30) signal or the Reverse rotation output (Y31) signal is output
according to the actual rotation direction of the motor.
• During pre-excitation (zero-speed or servo-lock function ON) in the speed or torque control mode, the Y30 and Y31 signals
are OFF.
• To use the Y30 signal, set "30 (positive logic)" or "130 (negative logic)" in any of
Pr.190 to Pr.196 (Output terminal
function selection)
to assign the function to an output terminal.
• To use the Y31 signal, set "31 (positive logic)" or "131 (negative logic)" in any of
Pr.190 to Pr.196 (Output terminal
function selection)
to assign the function to an output terminal.
NOTE
• The Y30 and Y31 signals are always OFF under V/F control, Advanced magnetic flux vector control, Real sensorless vector
control, and PM sensorless vector control.
• If the motor is rotated by an external force while the inverter is stopped, the Y30 and Y31 signals remain OFF.
Regenerative status output (Y32) signal
• When the motor gets in a regenerative braking (dynamic braking) state under Vector control, the Regenerative status
output (Y32) signal turns ON. Once the signal turns ON, the signal is retained ON for at least 100 ms.
• The signal is OFF during an inverter stop or during pre-excitation.
• To use the Y32 signal, set "32 (positive logic)" or "132 (negative logic)" in any of
Pr.190 to Pr.196 (Output terminal
function selection)
to assign the function to an output terminal.
NOTE
• The Y32 signal is always OFF under V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and
PM sensorless vector control.
Fault output (ALM) signal
• The fault signal (ALM signal) is output when an inverter protective function is activated.
Forward
rotation
Reverse
rotation
Time
Pre-excitation
Actual
motor
speed
ON
Y31
Y30
ON
Time
OFF
ON
ON
Signal is retained for 100 ms.
Y32
Regeneration
-
Driving
+
Less than 100 ms
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...