8. (E) Environment Setting Parameters
8.6 Automatic frequency setting / key lock operation selection
1
2
3
4
5
6
7
8
9
10
8.6
Automatic frequency setting / key lock operation
selection
Turing the setting dial or pressing the UP/DOWN key on the operation panel enables frequency setting without pressing the
SET key.
The key operation of the operation panel can be disabled.
Automatic frequency setting (Pr.161 = "1 or 11")
• To set the frequency using the operation panel when
Pr.161
= "0" (initial value) or "10", change the frequency value using
the setting dial or the UP/DOWN key, and press the SET key to confirm the setting (the value is stored in the RAM and
EEPROM).
• When
Pr.161
= "1 or 11", the automatic frequency setting is enabled. After the frequency value is changed using the setting
dial or the UP/DOWN key, the value indicated is stored in the RAM. If the frequency value has not been changed for 10
seconds, the value is stored in the EEPROM.
NOTE
• If the operation panel does not have the operation command source (
Pr.551
= "2, 3, or 9999" (with USB and/or PU
connection)), the frequency cannot be set using the operation panel.
• If the operation mode is changed to one in which the inverter does not operate according to the frequency set on the operation
panel after the frequency value is stored in the RAM but before it is stored in the EEPROM, the value is not stored in the
EEPROM.
• If the power is OFF or the inverter is reset after the frequency value is stored in the RAM but before it is stored in the EEPROM,
the value is not stored in the EEPROM.
• When setting the frequency by turning the setting dial, the frequency goes up to the set value of
Pr.1 Maximum frequency
.
Be aware of what frequency
Pr.1
is set to, and adjust the setting of
Pr.1
according to the application.
Pr.
Name
Initial value Setting range
Description
161
E200
Frequency setting/key lock
operation selection
0
0
Automatic frequency setting disabled
Key lock function
disabled.
1
Automatic frequency setting enabled
10
Automatic frequency setting disabled
Key lock function
enabled.
11
Automatic frequency setting enabled
Set frequency written and complete
When the MODE key is pressed or after 5 seconds
Alternating
Set frequency written and complete
(set frequency stored to RAM and EEPROM)
Alternating
Blinking
When the automatic frequency setting is enabled (Pr.161 = "1 or 11")
When the automatic frequency setting is disabled (Pr.161 = "0 (initial value) or 10")
Set frequency stored to RAM
After 10
seconds
Blinking
Set frequency stored to EEPROM
Within
5 seconds
Содержание FR-E800
Страница 17: ...16 1 Introduction 1 3 Related manuals MEMO ...
Страница 51: ...50 2 Basic Operation 2 8 I O terminal function assignment MEMO ...
Страница 89: ...88 3 Parameters 3 4 Parameter list by function group number MEMO ...
Страница 135: ...134 5 Speed Control 5 9 Troubleshooting in the speed control MEMO ...
Страница 153: ...152 6 Torque Control 6 7 Troubleshooting in torque control MEMO ...
Страница 195: ...194 8 E Environment Setting Parameters 8 18 Current average value monitor signal MEMO ...
Страница 237: ...236 10 D Operation Command and Frequency Command 10 6 Operation by multi speed setting MEMO ...
Страница 339: ...338 13 T Multi Function Input Terminal Parameters 13 9 Start signal operation selection MEMO ...
Страница 455: ...454 16 G Control Parameters 16 13 Speed smoothing control MEMO ...
Страница 481: ...480 18 Appendix 18 4 Parameters functions and instruction codes under different control methods MEMO ...