142
Function assignment of external terminal and control
4.11.3
Condition selection of function validity by second function selection signal (RT)
When the RT signal turns ON, the second function becomes valid.
For the RT signal, set "3" in any of
Pr. 178 to Pr. 184 (input terminal function selection)
to assign the function.
The second function has the following applications.
(a) Switching between normal use and emergency use
(b) Switching between heavy load and light load
(c) Changing of acceleration/deceleration time by broken line acceleration/deceleration
(d) Switching of characteristic between the main motor and sub motor
When the RT signal is ON, the following second function is selected at the same time.
You can select the second function using the RT signal.
Second function connection diagram
Second acceleration/deceleration time
Function
First Function
Parameter Number
Second Function
Parameter Number
Refer to
Page
Torque boost
Pr. 0
Pr. 46
Base frequency
Pr. 3
Pr. 47
Acceleration time
Pr. 7
Pr. 44
Deceleration time
Pr. 8
Pr. 44, Pr. 45
Electronic thermal O/L relay
Pr. 9
Pr. 51
Stall prevention
Pr. 22
Pr. 48
Applied motor
Pr. 71
Pr. 450
NOTE
Changing the terminal assignment using
Pr. 178
to
Pr. 184
(input terminal function selection)
may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 178 to Pr. 184 (input terminal function selection)
STF(STR)
SD
Inverter
Start
Second function
selection
RT
High speed
RH
Middle speed
RM
RT
Output frequency
Acceleration time
is reflected
Time
RH
RM
Содержание FR-E710W-0.1K
Страница 49: ...40 MEMO ...
Страница 65: ...56 MEMO ...
Страница 288: ...288 MEMO ...
Страница 310: ...310 MEMO ...
Страница 334: ...334 MEMO ...
Страница 335: ...335 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 348: ...4 4 BCN C22005 679 MEMO BCN C22005 679 fm 4 ページ 2014年11月7日 金曜日 午前11時58分 ...