Terminal connection diagram
Wiring
3 - 4
3.2 Terminal
connection
diagram
I002176E
Fig. 3-3:
Terminal connection diagram of the inverter
R/L1
P1
P/ +
PR N/-
S/L2
T/L3
U
V
W
STR
STF
RH
RM
RL
SD
PC
RUN
SE
A
B
C
2
10(+5V)
2
3
1
4
(+)
(-)
5
*4
*1
*8
*2
*3
*5
SINK
SOURCE
V
I
*5
AM
5
(+)
(-)
*7
*9
*6
*6
24V
L1
N
S1
S2
SC
SO
24V
Source Logic
Main circuit terminal
Control circuit terminal
Jumper
*1 DC reactor
When connecting a DC reactor, remove the
jumper across P1 and P/+.
Motor
3-phase AC
power supply
Main circuit
Control circuit
Terminal functions vary
with the input terminal
assignment set in
Pr. 178 to Pr. 182.
Control input signals (No voltage input allowed)
Forward
rotation start
Reverse
rotation start
High speed
Middle speed
Low speed
Multi-speed
selection
Contact input common (sink*)
24V DC power supply/
max. 100mA load current
Contact input common (source*)
*(Common for external power supply transistor)
Frequency setting signal (analog)
0–10V DC
4–20 mA DC
0–5V DC
0–10V DC
PU
connector
*4 It is recommended to use
1k
Ω/
2W when the
frequency setting signal is
changed frequently.
Relay output
(Alarm output)
Relay output
Running
Terminal functions vary with
the input terminal assignment
set in Pr. 192.
Open collector output common
Sink/source common
Safety monitor output common
Analog signal output
(0–10V DC)
Frequency
setting
potentiometer
1k
Ω,
1/2W
M
3~
Earth
Brake unit
(Option)
*8 Brake resistor (FR-ABR)
Install a thermal relay to prevent an overheat
and burnout of the brake resistor.
(The brake resistor can not be connected to
the FR-D720S-008SC and 014SC.).
Earth
Terminal functions vary with the input
terminal assignment set in Pr. 190.
Open collector output
0–5V DC
Voltage/current
input switch
Terminal 4
input
(Current input)
Analog common
*7 A brake transistor is not built-in to the
FR-D720S-008SC and 014SC.
1-phase AC
power supply
Inrush
current limit
circuit
*6 FR-D720S-008SC to 100SC: +, –
FR-D740-012SC to 160SC: P/+, N/–
*2 When using terminals PC-SD as a 24V DC power supply,
take care not to short across terminals PC-SD.
Output shutoff
circuit
Safety stop signal
Safety stop input (Channel 1)
Shorting wire
Safety stop input common
Safety monitor output
Terminal functions vary by Pr. 197
*9 Common terminal of terminal SO is terminal SE.
Single-phase power input
*3 Terminal input
specifications can be
changed by analog input
specifications switchover
(Pr. 73) (initial settings in
frame). Terminal 10 and
terminal 2 are used as PTC
input terminal (Pr. 561).
*5 Terminal input specifications can be changed by analog
input specifications switchover (Pr. 267) (initial settings in
frame).
Set the voltage/current input switch in the "V" position to
select voltage input (0 to 5 V/0 to 10 V) and "I" to select
current input (0/4 to 20 mA.)
To use terminal 4 (initial setting is current input), set "4" in
any of Pr.178 to Pr.182 to assign the function.
Safety stop input (Channel 2)
MC
MCCB
MC
MCCB
Earth
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......