Installation
Enclosure design
FR-D700 SC EC
2 - 7
2.4 Enclosure
design
When an inverter enclosure is to be designed and manufactured, heat generated by contained
equipment, etc., the environment of an operating place, and others must be fully considered to
determine the enclosure structure, size and equipment layout.
The inverter unit uses many semiconductor devices. To ensure higher reliability and long period
of operation, operate the inverter in the ambient environment that completely satisfies the equip-
ment specifications.
2.4.1
Inverter installation environment
As the inverter installation environment should satisfy the standard specifications indicated in
the following table, operation in any place that does not meet these conditions not only deteri-
orates the performance and life of the inverter, but also causes a failure. Refer to the following
points and take adequate measures.
Temperature
The permissible ambient temperature of the inverter FR-D700 SC is between
−
10 and +50°C.
Always operate the inverter within this temperature range. Operation outside this range will con-
siderably shorten the service lives of the semiconductors, parts, capacitors and others. Take the
following measures so that the ambient temperature of the inverter falls within the specified
range.
●
Measures against high temperature
– Use a forced ventilation system or similar cooling system. (Refer to page 2-10.)
– Install the enclosure in an air-conditioned electrical chamber.
– Block direct sunlight.
– Provide a shield or similar plate to avoid direct exposure to the radiated heat and wind
of a heat source.
– Ventilate the area around the enclosure well.
●
Measures against low temperature
– Provide a space heater in the enclosure.
– Do not power off the inverter. (Keep the start signal of the inverter off.)
●
Sudden temperature changes
– Select an installation place where temperature does not change suddenly.
– Avoid installing the inverter near the air outlet of an air conditioner.
– If temperature changes are caused by opening/closing of a door, install the inverter away
from the door.
Item
Specification
Ambient temperature
−
10°C to +50°C (non-freezing)
Ambient humidity
90% RH or less (non-condensing)
Atmosphere
Free from corrosive and explosive gases, dust and dirt
Maximum altitude
1000m or less
Vibration
5.9m/s
2
or less (0,6 g) at 10 to 55Hz (directions of X, Y, Z axes)
Tab. 2-1:
Environmental standard specifications of inverter
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......