Monitor display and monitor output signals
Parameter
6 - 120
6.10.4
Terminal AM calibration [C1 (Pr.901)]
By using the operation panel or parameter unit, you can calibrate terminal AM to full scale de-
flection.
The above parameter can be set when Pr. 160 = 0.
The parameter number in parentheses is the one for use with the operation panel (FR-PA02) for
the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
The above parameters allow its setting to be changed during operation in any operation mode
even if "0" (initial value) is set in Pr. 77 "Parameter write selection".
Terminal AM gain calibration [C1 (Pr. 901)]
Terminal AM is factory-set to provide a 10V DC output in the full-scale status of the correspond-
ing monitor item. Calibration parameter C1 (Pr. 901) allows the output voltage ratios (gains) to
be adjusted according to the meter scale. Note that the maximum output voltage is 10V DC, the
maximum output current 1mA.
Pr. No.
Name
Initial
Value
Setting
Range
Description
Parameters referred to
Refer to
Section
C1
(901)
AM terminal
calibration
—
—
Calibrates the scale of the meter con-
nected to terminal AM.
55
56
158
Frequency moni-
toring reference
Current monitor-
ing reference
AM terminal
function selection
Fig. 6-65:
Connecting an analog meter to the AM output
I001168C
Fig. 6-66:
Terminal AM gain calibration
I001932E
10V DC
Output
signal
Gain calibration
of output signal
(Pr. 901)
Terminal AM
output
Содержание FR-D720S SC EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the case Product checking and part identification 1 4 ...
Страница 108: ...Operation panel Operation 4 20 ...
Страница 436: ...Setting for the parameter unit and operation panel Parameter 6 286 ...
Страница 484: ...Measurements on the main circuit Maintenance and inspection 8 14 ...
Страница 504: ...Specification change Appendix A 20 ...
Страница 505: ......
Страница 506: ......
Страница 510: ...Index Appendix A 24 ...
Страница 511: ......